El CRAI romandrà tancat del 24 de desembre de 2025 al 6 de gener de 2026. La validació de documents es reprendrà a partir del 7 de gener de 2026.
El CRAI permanecerá cerrado del 24 de diciembre de 2025 al 6 de enero de 2026. La validación de documentos se reanudará a partir del 7 de enero de 2026.
From 2025-12-24 to 2026-01-06, the CRAI remain closed and the documents will be validated from 2026-01-07.
 
Carregant...
Miniatura

Tipus de document

Article

Versió

Versió acceptada

Data de publicació

Tots els drets reservats

Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/98263

Strategies for the multi-residue analysis of 100 pesticides by liquid chromatography-triple quadrupole mass spectrometry

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

Analytical strategies for screening, quantitation and confirmation of a group of 100 pesticides in fruit and vegetable samples by LC-MS and LC-MS/MS were developed. The pesticides studied belong to different chemical families of herbicides, insecticides and fungicides. A selection of some degradation products was also included. Chromatographic separation was performed using a Zorbax Eclipse XDB-C8 column (150 mm × 4.6 mm and 5 µm particle size), and gradient elution with acetonitrile-water (both with 0.1% formic acid) as mobile phase. LC-MS/MS using highly-selective selected reaction monitoring (H-SRM) acquisition mode monitoring two transitions for each compound showed to be the most sensitive methodology. Quantitation was carried out using matrix-matched standard calibration and good linearity of response was demonstrated (r > 0.998). Limits of detection (by acquiring two transitions and with the ion-ratio requirements) ranged between 0.01 and 20 µg/kg were obtained. So, in general, the sensitivity achieved meets the maximum residue levels (MRLs) established by the European Union regulation for food monitoring programs. Pesticide confirmation was carried out following European Union guidelines. In order to prevent false-positives, further confirmatory strategies were proposed. LC-MS in highly-selective selected ion monitoring (H-SIM) mode with accurate mass measurement was used to obtain an orthogonal criterion (exact mass) for confirmation. Accurate mass measurements were always bellow 0.9 mDa for almost all pesticides studied (similar to those described with TOF instruments). A user reversed energy ramp (RER) product ion scan spectra library was generated by means of a data dependent analysis for routine library searching of pesticides. The combination of LC-MS/MS in H-SRM mode and the generation of the RER product ion scan spectra and library search were then used to achieve further confirmation on pesticide analysis. The LC-MS and LC-MS/MS strategies developed were successfully applied for the analysis and confirmation of pesticides in different types of fruit and vegetables samples, and examples of the screening, quantitation and confirmation of pesticides in these samples are shown in this work.

Citació

Citació

NÚÑEZ BURCIO, Oscar, GALLART AYALA, Hèctor, FERRER, Imma, MOYANO MORCILLO, Encarnación, GALCERÁN HUGUET, M. teresa. Strategies for the multi-residue analysis of 100 pesticides by liquid chromatography-triple quadrupole mass spectrometry. _Journal of Chromatography A_. 2012. Vol. 1249, núm. 164-180. [consulta: 25 de desembre de 2025]. ISSN: 0021-9673. [Disponible a: https://hdl.handle.net/2445/98263]

Exportar metadades

JSON - METS

Compartir registre