El CRAI romandrà tancat del 24 de desembre de 2025 al 6 de gener de 2026. La validació de documents es reprendrà a partir del 7 de gener de 2026.
El CRAI permanecerá cerrado del 24 de diciembre de 2025 al 6 de enero de 2026. La validación de documentos se reanudará a partir del 7 de enero de 2026.
From 2025-12-24 to 2026-01-06, the CRAI remain closed and the documents will be validated from 2026-01-07.
 

A wearable biosensor for sweat lactate as a proxy for sport performance monitoring

dc.contributor.authorXuan, Xing
dc.contributor.authorChen, Chen
dc.contributor.authorPérez Ràfols, Clara
dc.contributor.authorSwarén, Mikael
dc.contributor.authorWedholm, Lars
dc.contributor.authorCuartero, María
dc.contributor.authorCrespo, Gastón A.
dc.date.accessioned2023-02-15T18:39:14Z
dc.date.available2023-02-15T18:39:14Z
dc.date.issued2022-08-19
dc.date.updated2023-02-15T18:39:14Z
dc.description.abstractIn the last decade, sport performance assessment has significantly transformed due to the appearance of disruptive technologies. Subjective pen and paper notations have evolved into advanced wearable sensing systems that acquire performance-related data. The selection of adequate performance metric variables always causes a debate in sport physiology, and this becomes more relevant once new biochemical indicators are proposed, such as sweat lactate. Here, we analyze the correlation of real-time sweat lactate, obtained with a validated wearable biosensor, with the typical physiological parameters often recorded in sports laboratories (e. g., blood lactate, Borg scale for the rating of perceived exertion, heart rate, power output, blood glucose, and respiratory quotient). We found that the heart rate, power output, Borg scale, and blood lactate relate to sweat lactate in independent individuals during cycling activity. Hence, we demonstrate the potential to associate non-invasive, quantitative, and personalized analysis with sport practice.
dc.format.extent15 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec725261
dc.identifier.issn2629-2742
dc.identifier.urihttps://hdl.handle.net/2445/193689
dc.language.isoeng
dc.publisherChemistry Europe
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1002/anse.202200047
dc.relation.ispartofAnalysis & Sensing, 2022, num. e202200, p. 1-15
dc.relation.urihttps://doi.org/10.1002/anse.202200047
dc.rightscc-by-nc-nd (c) Xuan, Xing et al., 2022
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationBiosensors
dc.subject.classificationMonitoratge de pacients
dc.subject.classificationElectroquímica
dc.subject.otherBiosensors
dc.subject.otherPatient monitoring
dc.subject.otherElectrochemistry
dc.titleA wearable biosensor for sweat lactate as a proxy for sport performance monitoring
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
725261.pdf
Mida:
8.22 MB
Format:
Adobe Portable Document Format