Composite Electrodes Based on Carbon Materials Decorated with Hg Nanoparticles for the Simultaneous Detection of Cd(II), Pb(II) and Cu(II)

dc.contributor.authorFernández, Laia L.
dc.contributor.authorBastos-Arrieta, Julio
dc.contributor.authorPalet, Cristina
dc.contributor.authorBaeza, Mireia
dc.date.accessioned2022-07-11T14:53:14Z
dc.date.available2022-07-11T14:53:14Z
dc.date.issued2022-04-15
dc.date.updated2022-07-11T14:53:15Z
dc.description.abstractMonitoring water quality has become a goal to prevent issues related to human health and environmental conditions. In this sense, the concentration of metal ions in water sources is screened, as these are considered persistent contaminants. In this work, we describe the implementation of customized graphite electrodes decorated with two types of Hg nanoparticles (Hg-NPs), optimized toward the electrochemical detection of Cd, Pb and Cu. Here, we combine Hg, a well-known property to form alloys with other metals, with the nanoscale features of Hg-NPs, resulting in improved electrochemical sensors towards these analytes with a substantial reduction in the used Hg amount. Hg-NPs were synthesized using poly(diallyldimethylammonium) chloride (PDDA) in a combined role as a reducing and stabilizing agent, and then appropriately characterized by means of Transmission Electron Microscopy (TEM) and Zeta Potential. The surface of composite electrodes with optimized graphite content was modified by the drop-casting of the prepared Hg-NPs. The obtained nanocomposite electrodes were morphologically characterized by Scanning Electron Microscopy (SEM), and electrochemically by Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS). The results show that the Hg-NP-modified electrodes present better responses towards Cd(II), Pb(II) and Cu(II) detection in comparison with the bare graphite electrode. Analytical performance of sensors was evaluated by square-wave anodic stripping voltammetry (SWASV), obtaining a linear range of 0.005-0.5 mg·L−1 for Cd2+, of 0.028-0.37 mg·L−1 for Pb2+ and of 0.057-1.1 mg·L−1 for Cu2+. Real samples were analyzed using SWASV, showing good agreement with the recovery values of inductively coupled plasma-mass spectrometry (ICP-MS) measurements
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec723203
dc.identifier.issn2227-9040
dc.identifier.urihttps://hdl.handle.net/2445/187529
dc.language.isoeng
dc.publisherMDPI
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/chemosensors10040148
dc.relation.ispartofChemosensors, 2022, vol. 10, num. 4, p. 145
dc.relation.urihttps://doi.org/10.3390/chemosensors10040148
dc.rightscc-by (c) Fernández, Laia L. et al., 2022
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationNanopartícules
dc.subject.classificationGrafit
dc.subject.classificationVoltametria
dc.subject.otherNanoparticles
dc.subject.otherGraphite
dc.subject.otherVoltammetry
dc.titleComposite Electrodes Based on Carbon Materials Decorated with Hg Nanoparticles for the Simultaneous Detection of Cd(II), Pb(II) and Cu(II)
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
723203.pdf
Mida:
3.17 MB
Format:
Adobe Portable Document Format