An Instantaneous low-cost point-of-care anemia detection device

dc.contributor.authorPunter Villagrasa, Jaime
dc.contributor.authorCid Vidal, Joan
dc.contributor.authorPáez Avilés, Cristina
dc.contributor.authorRodríguez-Villarreal, Ivón
dc.contributor.authorJuanola, Esteve
dc.contributor.authorColomer i Farrarons, Jordi
dc.contributor.authorMiribel-Català, Pere Ll. (Pere Lluís)
dc.date.accessioned2020-03-10T11:02:42Z
dc.date.available2020-03-10T11:02:42Z
dc.date.issued2015-02-16
dc.date.updated2020-03-10T11:02:42Z
dc.description.abstractWe present a small, compact and portable device for point-of-care instantaneous early detection of anemia. The method used is based on direct hematocrit measurement from whole blood samples by means of impedance analysis. This device consists of a custom electronic instrumentation and a plug-and-play disposable sensor. The designed electronics rely on straightforward standards for low power consumption, resulting in a robust and low consumption device making it completely mobile with a long battery life. Another approach could be powering the system based on other solutions like indoor solar cells, or applying energy-harvesting solutions in order to remove the batteries. The sensing system is based on a disposable low-cost label-free three gold electrode commercial sensor for 50 µL blood samples. The device capability for anemia detection has been validated through 24 blood samples, obtained from four hospitalized patients at Hospital Clínic. As a result, the response, effectiveness and robustness of the portable point-of-care device to detect anemia has been proved with an accuracy error of 2.83% and a mean coefficient of variation of 2.57% without any particular case above 5%.
dc.format.extent14 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec649191
dc.identifier.issn1424-8220
dc.identifier.pmid25690552
dc.identifier.urihttps://hdl.handle.net/2445/152311
dc.language.isoeng
dc.publisherMDPI
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/s150204564
dc.relation.ispartofSensors, 2015, vol. 15, num. 2, p. 4564-4577
dc.relation.urihttps://doi.org/10.3390/s150204564
dc.rightscc-by (c) Punter Villagrasa, Jaime et al., 2015
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es
dc.sourceArticles publicats en revistes (Enginyeria Electrònica i Biomèdica)
dc.subject.classificationEspectroscòpia d'impedància
dc.subject.classificationSang
dc.subject.classificationElectrònica
dc.subject.otherImpedance spectroscopy
dc.subject.otherBlood
dc.subject.otherElectronics
dc.titleAn Instantaneous low-cost point-of-care anemia detection device
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion