Carregant...
Miniatura

Tipus de document

Article

Versió

Versió acceptada

Data de publicació

Llicència de publicació

cc-by-nc-nd (c) Elsevier B.V., 2018
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/187935

Thermal desorption-ion mobility spectrometry: A rapid sensor for the detection of cannabinoids and discrimination of Cannabis Sativa L. chemotypes

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

Existing analytical techniques used for the determination of cannabinoids in Cannabis sativa L. (Cannabis) plants mostly rely on chromatography-based methods. As a rapid alternative for the direct analysis of them, thermal desorption (TD)-ion mobility spectrometry (IMS) was used for obtaining spectral fingerprints of single cannabinoids from Cannabis plant extracts and from plant residues on hands after their manipulation. The ionization source was 63Ni, with automatic switchable polarity. Although in both ionization modes there were signals in the TD-IMS spectra of the plant extracts and residues that could be assigned to concrete cannabinoids and chemotypes, most of them could not be clearly distinguished. Alternatively, the global spectral data of the plant extracts and residues were pre-processed and then, using principal component analysis (PCA)-linear discriminant analysis (LDA), grouped in function of their chemotype in a more feasible way. Using this approach, the possibility of false positive responses was also studied analyzing other non-Cannabis plants and tobacco, which were clustered in a different group to those of Cannabis. Therefore, TD-IMS, as analytical tool, and PCA-LDA, as a strategy for data reduction and pattern recognition, can be applied for on-site chemotaxonomic discrimination of Cannabis varieties and detection of illegal marijuana since the IMS equipment is portable and the analysis time is highly short.

Citació

Citació

CONTRERAS, María del mar, JURADO-CAMPOS, Natividad, SÁNCHEZ-CARNERERO CALLADO, Carolina, ARROYO-MANZANARES, Natalia, FERNÁNDEZ ROMERO, Luis, CASANO, Salvatore, MARCO COLÁS, Santiago, ARCE, Lourdes, FERREIRO-VERA, Carlos. Thermal desorption-ion mobility spectrometry: A rapid sensor for the detection of cannabinoids and discrimination of Cannabis Sativa L. chemotypes. _Sensors and Actuators B-Chemical_. 2018. Vol. 273, núm. 1413-1424. [consulta: 1 de febrer de 2026]. ISSN: 0925-4005. [Disponible a: https://hdl.handle.net/2445/187935]

Exportar metadades

JSON - METS

Compartir registre