Engineering a light-driven cyanine based molecular rotor to enhance the sensitivity towards a viscous medium.

dc.contributor.authorKachwal, Vishal
dc.contributor.authorSrivastava, Abhilasha
dc.contributor.authorThakar, Sumukh
dc.contributor.authorZubiria-Ulacia, Maria
dc.contributor.authorGautam, Diplesh
dc.contributor.authorMajumder, Syamantak
dc.contributor.authorVenkatesh, K.P.
dc.contributor.authorCasanova i Casas, David
dc.contributor.authorChowdhury, Rajdeep
dc.contributor.authorRath, Nigam P.
dc.contributor.authorMukherjee, Sudeshn
dc.contributor.authorAlemany i Cahner, Pere
dc.contributor.authorLaskar, Inamur Rahaman
dc.date.accessioned2022-02-24T17:58:48Z
dc.date.available2022-02-24T17:58:48Z
dc.date.issued2021-06-08
dc.date.updated2022-02-24T17:58:48Z
dc.description.abstractThis article describes the enhanced sensitivity to a viscous medium by a molecular rotor based fluorophore (RBF), TPSI I. The TPSI I molecule is designed in such a way that it consists of a rotor and a fluorophore with a p-rich bridge between them. TPSI I is a light-responsive material in solution as well as in the solid state. The structural design of the molecule allows flexible rotation and photo-induced cis-trans isomerization both in the solid state as well as in solution. These combined attributes of TPSI I are responsible for the ultrasensitive viscosity response of the new material, which was verified through the Fo ̈rster-Hoffmann equation. According to this equation, the derived 'x' value is 1.02 (x is related to the sensitivity) which is the highest among the contemporary reports for RBFs. The facts were evidenced both by experimental as well as theoretical data. The ultrasensitivity towards viscosity was further analyzed in in vitro studies by detecting the subtle changes in the alteration of intracellular viscosity in normal and cancerous cells. An alteration of intracellular viscosity in cells treated with viscosity modula- tors was also confirmed using a previously well-established viscosity measurement technique, dynamic measurement through the piezoelectric patch. Our research offers a detailed mechanism to improve viscosity sensors and an efficient probe for detecting minute changes in intracellular viscosity.
dc.format.extent10 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec714100
dc.identifier.issn2633-5409
dc.identifier.urihttps://hdl.handle.net/2445/183517
dc.language.isoeng
dc.publisherRoyal Society of Chemistry
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1039/d1ma00277e
dc.relation.ispartofMaterials Advances, 2021, vol. 2, p. 4804-4813
dc.relation.urihttps://doi.org/10.1039/d1ma00277e
dc.rightscc-by (c) Kachwal, Vishal et al., 2021
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceArticles publicats en revistes (Ciència dels Materials i Química Física)
dc.subject.classificationFluorescència
dc.subject.classificationViscositat
dc.subject.otherFluorescence
dc.subject.otherViscosity
dc.titleEngineering a light-driven cyanine based molecular rotor to enhance the sensitivity towards a viscous medium.
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
714100.pdf
Mida:
3.54 MB
Format:
Adobe Portable Document Format