Copper (II) oxide nanowires for p-type conductometric NH3 sensing
| dc.contributor.author | Shao, F. | |
| dc.contributor.author | Hernández Ramírez, Francisco | |
| dc.contributor.author | Prades García, Juan Daniel | |
| dc.contributor.author | Fàbrega i Claveria, Ma. Carme | |
| dc.contributor.author | Andreu Arbella, Teresa | |
| dc.contributor.author | Morante i Lleonart, Joan Ramon | |
| dc.date.accessioned | 2016-11-03T16:11:08Z | |
| dc.date.available | 2016-11-03T16:11:08Z | |
| dc.date.issued | 2014-08-31 | |
| dc.date.updated | 2016-11-03T16:11:13Z | |
| dc.description.abstract | Copper (II) oxide (CuO) is a metal oxide suitable for developing solid state gas sensors. Nevertheless, a detailed insight into the chemical-to-electrical transduction mechanisms between gas molecules and this metal oxide is still limited. Here, individual CuO nanowires were evaluated as ammonia (NH3) and hydrogen sulphide (H2S) sensors, validating the p-type character of this semiconductor. The working principle behind their performance was qualitatively modeled and it was concluded that adsorbed oxygen at the surface plays a key role necessary to explain the experimental data. Compared to their counterparts of SnO2 nanowires, an appreciable sensitivity enhancement to NH3 for concentrations below 100 ppm was demonstrated. | |
| dc.format.extent | 5 p. | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.idgrec | 644580 | |
| dc.identifier.issn | 0169-4332 | |
| dc.identifier.uri | https://hdl.handle.net/2445/103228 | |
| dc.language.iso | eng | |
| dc.publisher | Elsevier B.V. | |
| dc.relation.isformatof | Versió postprint del document publicat a: https://doi.org/10.1016/j.apsusc.2014.05.038 | |
| dc.relation.ispartof | Applied Surface Science, 2014, vol. 311, p. 177-181 | |
| dc.relation.uri | https://doi.org/10.1016/j.apsusc.2014.05.038 | |
| dc.rights | (c) Elsevier B.V., 2014 | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | |
| dc.source | Articles publicats en revistes (Enginyeria Electrònica i Biomèdica) | |
| dc.subject.classification | Nanotecnologia | |
| dc.subject.classification | Detectors de gasos | |
| dc.subject.classification | Detectors químics | |
| dc.subject.other | Nanotechnology | |
| dc.subject.other | Gas detectors | |
| dc.subject.other | Chemical detectors | |
| dc.title | Copper (II) oxide nanowires for p-type conductometric NH3 sensing | |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:eu-repo/semantics/acceptedVersion |