dc.description.abstractTwo in-line enrichment procedures (large volume sample stacking (LVSS) and field amplified sample injection (FASI)) have been evaluated for the capillary zone electrophoresis (CZE) analysis of haloacetic acids (HAAs) in drinking water. For LVSS, separation on normal polarity by using 20 mM acetic acid-ammonium acetate (pH 5.5) containing 20% acetonitrile as BGE was required. For FASI, the optimum conditions were 25 s hydrodynamic injection (3.5 kPa) of a water plug followed by 25 s electrokinetic injection (-10 kV) of the sample, and 200 mM formic acid-ammonium formate buffer at pH 3.0 as BGE. For both FASI and LVSS methods, linear calibration curves (r2>0.992), limit of detection (LOD) on standards prepared in Milli-Q water (49.1-200 µg/L for LVSS and 4.2-48 µg/L for FASI), and both run-to-run and day-to-day precisions (RSD values up to 15.8% for concentration) were established. Due to the higher sensitive enhancement (up to 310-fold) achieved with FASI-CZE this method was selected for the analysis of HAAs in drinking water. However, for an optimal FASI application sample salinity was removed by solid phase extraction (SPE) using Oasis WAX cartridges. With SPE-FASI-CZE, method detection limits in the range 0.05-0.8 µg/L were obtained, with recoveries, in general, higher than 90% (around 65% for monochloroacetic and monobromoacetic acids). The applicability of the SPE-FASI-CZE method was evaluated by analyzing a drinking tap water from Barcelona where seven HAAs were found at concentration levels between 3-13 µg/L.
dc.format.extent23 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec596566
dc.identifier.issn0173-0835
dc.identifier.pmid21766475
dc.identifier.urihttps://hdl.handle.net/2445/98197
dc.language.isoeng
dc.publisherWiley-VCH
dc.relation.isformatofVersió postprint del document publicat a: http://dx.doi.org/10.1002/elps.201000676
dc.relation.ispartofElectrophoresis, 2011, vol. 32, num. 16, p. 2123-2130
dc.relation.urihttp://dx.doi.org/10.1002/elps.201000676
dc.rights(c) Wiley-VCH, 2011
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationAcetats
dc.subject.classificationAigua potable
dc.subject.classificationElectroforesi capil·lar
dc.subject.classificationContaminants
dc.subject.otherAcetates
dc.subject.otherDrinking water
dc.subject.otherCapillary electrophoresis
dc.subject.otherPollutants
dc.titleIn-line preconcentration capillary zone electrophoresis for the analysis of haloacetic acids in water
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
596566.pdf
Mida:
273.86 KB
Format:
Adobe Portable Document Format