A High Dynamic Range ASIC for Time of Flight PET with monolithic crystals

dc.contributor.authorGómez, Sergio
dc.contributor.authorSanmukh, Anand
dc.contributor.authorGascón Fora, David
dc.contributor.authorSánchez, David
dc.contributor.authorMauricio Ferré, Joan
dc.contributor.authorGraciani Díaz, Ricardo
dc.contributor.authorManera Escalero, Rafel
dc.contributor.authorGarrido Beltrán, Lluís
dc.contributor.authorFernández Varea, José María
dc.contributor.authorCela, J.M.
dc.contributor.authorFreixas, L.
dc.contributor.authorMarín, J.
dc.contributor.authorNavarrete, J.J.
dc.contributor.authorOller, J.C.
dc.contributor.authorPérez, J.M.
dc.contributor.authorRato, Pedro
dc.contributor.authorVela Mendes, O.
dc.date.accessioned2020-12-17T11:48:18Z
dc.date.available2020-12-17T11:48:18Z
dc.date.issued2019-07-25
dc.date.updated2020-12-17T11:48:18Z
dc.description.abstractThe HRFlexToT is a 16-channel ASIC for SiPM anode readout designed for Positron Emission Tomography (PET) applications that features high dynamic range (>8 bits), low input impedance, common cathode connection, high speed and low power (~3.5 mW/ch). The ASIC has been manufactured using XFAB 0.18 mm CMOS technology. The main characteristics of the HRFlexToT, compared to its predecessor, are a new energy measurement readout providing a linear Time Over Threshold (ToT) with an extended dynamic range, lower power consumption and better timing response. Initial measurements show a linearity error below 3%. Single Photon Time Resolution (SPTR) measurements performed using a Hamamatsu MPPC S13360-3050CS (3x3 mm2 pixel, 50 umm cell) shows 30% improvement with respect to the previous version of the ASIC, setting this specification in the order of 141 ps FWHM and reducing 3 times power consumption. It is important to highlight that an SPTR of 141 ps FWHM is, according to the best of our knowledge, the best resolution achieved so far for this sensor. Coincidence Time Resolution (CTR) measurements are expected to be performed during 2018.
dc.format.extent4 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec705328
dc.identifier.issn1824-8039
dc.identifier.urihttps://hdl.handle.net/2445/172835
dc.language.isoeng
dc.publisherScuola Internazionale Superiore di Studi Avanzati (SISSA)
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.22323/1.343.0085
dc.relation.ispartofProceedings of Science, 2019, vol. 343
dc.relation.urihttps://doi.org/10.22323/1.343.0085
dc.rightscc-by-nc-nd (c) Gómez, S. et al., 2019
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.sourceArticles publicats en revistes (Institut de Ciències del Cosmos (ICCUB))
dc.subject.classificationCircuits integrats d'aplicació específica
dc.subject.classificationTomografia per emissió de positrons
dc.subject.otherApplication-specific integrated circuits
dc.subject.otherPositron emission tomography
dc.titleA High Dynamic Range ASIC for Time of Flight PET with monolithic crystals
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
705328.pdf
Mida:
403.96 KB
Format:
Adobe Portable Document Format