Carregant...
Miniatura

Tipus de document

Article

Versió

Versió publicada

Data de publicació

Llicència de publicació

cc-by-nc (c) Nogueira D.R. et al., 2014
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/97209

Determination of Methotrexate in pH-Sensitive Chitosan Nanoparticles by Validated RP-LC and UV Spectrophotometric Methods

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

Nanotechnology-based drug delivery systems are in constant development and, therefore, it is of great importance to have rapid, efficient and accurate analytical methodology to quantify the encapsulated drugs. Here, simple and fast methods, by reversed-phase liquid chromatography (RP-LC) and UV spectrophotometry, were developed and validated for the determination of methotrexate (MTX) in pH-sensitive chitosan nanoparticles (CS-NPs). NPs were prepared using a modified ionotropic complexation process, in which was included a surfactant derived from Nα,Nε-dioctanoyl lysine with an inorganic sodium counterion. The RP-LC method was carried out on a Waters XBridgeTM C18 column (250 mm x 4.6 mm I.D., 5μm), with mobile phase consisted of potassium phosphate buffer (0.05 M, pH 3.2): acetonitrile (86:14, v/v), and UV detection set at 303 nm. The analyses of MTX content by the UV method were also accomplished at 303 nm, using 0.1 M sodium hydroxide as diluent. The measurements were linearly correlated with concentration for both methods in the 1 - 30 μg/mL range (r > 0.9999). The specificity tests showed that there was no interference of the NP components on the quantitative analyses. Precision (repeatability and intermediate precision) was demonstrated by a relative standard deviation lower than 1.5%, whereas the accuracy was assessed by the recovery of MTX from sample matrices, given mean value of ~99%. The proposed methods were applied for the analyses of MTX in different batches of NPs, and the results showed non-significant differences (p > 0.05) between the values obtained with both methodologies. Moreover, the RP-LC method was successfully used to determine the drug entrapment efficiency, and to quantify MTX during in vitro release assays and photolytic degradation studies. In conclusion, the validated methods are suitable to assay MTX in pH-sensitive CS-NPs without any interference from the polymer or surfactant.

Citació

Citació

NOGUEIRA, Daniele r., MACEDO, Letícia b., SCHEEREN, Laís e., MITJANS ARNAL, Montserrat, INFANTE MARTÍNEZ-PARDO, Ma. rosa, ROLIM, Clarice m. b., VINARDELL MARTÍNEZ-HIDALGO, Ma. pilar. Determination of Methotrexate in pH-Sensitive Chitosan Nanoparticles by Validated RP-LC and UV Spectrophotometric Methods. _Journal of Applied Biopharmaceutics and Pharmacokinetics _. 2014. Vol. 2, núm. 2, pàgs. 59-67. [consulta: 9 de gener de 2026]. ISSN: 2309-4435. [Disponible a: https://hdl.handle.net/2445/97209]

Exportar metadades

JSON - METS

Compartir registre