Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Document type

Article

Version

Published version

Publication date

Publication license

cc-by-nc (c) Nogueira D.R. et al., 2014
Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/97209

Determination of Methotrexate in pH-Sensitive Chitosan Nanoparticles by Validated RP-LC and UV Spectrophotometric Methods

Journal Title

Director/Tutor

Journal ISSN

Volume Title

Abstract

Nanotechnology-based drug delivery systems are in constant development and, therefore, it is of great importance to have rapid, efficient and accurate analytical methodology to quantify the encapsulated drugs. Here, simple and fast methods, by reversed-phase liquid chromatography (RP-LC) and UV spectrophotometry, were developed and validated for the determination of methotrexate (MTX) in pH-sensitive chitosan nanoparticles (CS-NPs). NPs were prepared using a modified ionotropic complexation process, in which was included a surfactant derived from Nα,Nε-dioctanoyl lysine with an inorganic sodium counterion. The RP-LC method was carried out on a Waters XBridgeTM C18 column (250 mm x 4.6 mm I.D., 5μm), with mobile phase consisted of potassium phosphate buffer (0.05 M, pH 3.2): acetonitrile (86:14, v/v), and UV detection set at 303 nm. The analyses of MTX content by the UV method were also accomplished at 303 nm, using 0.1 M sodium hydroxide as diluent. The measurements were linearly correlated with concentration for both methods in the 1 - 30 μg/mL range (r > 0.9999). The specificity tests showed that there was no interference of the NP components on the quantitative analyses. Precision (repeatability and intermediate precision) was demonstrated by a relative standard deviation lower than 1.5%, whereas the accuracy was assessed by the recovery of MTX from sample matrices, given mean value of ~99%. The proposed methods were applied for the analyses of MTX in different batches of NPs, and the results showed non-significant differences (p > 0.05) between the values obtained with both methodologies. Moreover, the RP-LC method was successfully used to determine the drug entrapment efficiency, and to quantify MTX during in vitro release assays and photolytic degradation studies. In conclusion, the validated methods are suitable to assay MTX in pH-sensitive CS-NPs without any interference from the polymer or surfactant.

Citation

Citation

NOGUEIRA, Daniele R., et al. Determination of Methotrexate in pH-Sensitive Chitosan Nanoparticles by Validated RP-LC and UV Spectrophotometric Methods. Journal of Applied Biopharmaceutics and Pharmacokinetics . 2014. Vol. 2, num. 2, pags. 59-67. ISSN 2309-4435. [consulted: 11 of August of 2026]. Available at: https://hdl.handle.net/2445/97209

Export metadata

JSON - METS

Share record