Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Determination of chromium(VI) with screen-printed ex-situ bismuth film electrodes by adsorptive stripping voltammetry

dc.contributor.authorTriviño, Juan José
dc.contributor.authorEsteban i Cortada, Miquel
dc.contributor.authorDíaz Cruz, José Manuel
dc.contributor.authorSerrano i Plana, Núria
dc.contributor.authorAlvarez-Lueje, Alejandro
dc.contributor.authorArancibia, Verónica
dc.date.accessioned2025-06-13T16:44:33Z
dc.date.available2025-12-31T06:10:41Z
dc.date.issued2025-01-01
dc.date.updated2025-06-13T16:44:33Z
dc.description.abstractThis work presents a fast and sensitive method, with an ex–situ bismuth film screen-printed carbon electrode (ex–situ Bi–SPCE), for the determination of Cr(VI) through adsorptive stripping voltammetry (AdSV) using Pyrogallol Red (PGR) ascomplexing agent. The method is based on the oxidation of PGR by Cr(VI) and posterior complexation with Cr(III). To obtaina sensitive and selective method, the effects of various parameters such as pH, ligand concentration of PGR (CPGR),accumulation potential, and accumulation time (Eacc, tacc) were optimized. The optimal conditions using Bi–SPCE preparedex–situ were pH 4.5 (0.01 molL<sup>-1</sup> acetic acid/acetate buffer), CPGR: 2.6 μmolL<sup>-1</sup>, Eacc: - 0.70 V and tacc: 60 s. Peak current isproportional to Cr(VI) concentration over the range 0.23–12.0 μgL<sup>-1</sup>, with a 3σ detection limit of 0.97 μgL<sup>-1</sup>. The method wasvalidated by determining Cr(VI) in tap water spiked with Cr(VI) and Cr(III).
dc.format.extent10 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec755193
dc.identifier.issn1040-0397
dc.identifier.urihttps://hdl.handle.net/2445/221533
dc.language.isoeng
dc.publisherWiley-VCH
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/https://doi.org/10.1002/elan.202400218
dc.relation.ispartofElectroanalysis, 2025, vol. 37, p. 1-10
dc.relation.urihttps://doi.org/https://doi.org/10.1002/elan.202400218
dc.rights(c) Wiley-VCH, 2025
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationAdsorció
dc.subject.classificationVoltametria
dc.subject.classificationCrom
dc.subject.otherAdsorption
dc.subject.otherVoltammetry
dc.subject.otherChromium
dc.titleDetermination of chromium(VI) with screen-printed ex-situ bismuth film electrodes by adsorptive stripping voltammetry
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
881577.pdf
Mida:
849.17 KB
Format:
Adobe Portable Document Format