Multivariate standard addition for the analysis of overlapping voltammetric signals in the presence of matrix effects: Application to the simultaneous determination of hydroquinone and catechol

dc.contributor.authorMartínez, Kassandra
dc.contributor.authorAriño Blasco, Cristina
dc.contributor.authorDíaz Cruz, José Manuel
dc.contributor.authorSerrano i Plana, Núria
dc.contributor.authorEsteban i Cortada, Miquel
dc.date.accessioned2018-05-23T16:28:13Z
dc.date.available2020-07-15T05:10:20Z
dc.date.issued2018-07-15
dc.date.updated2018-05-23T16:28:13Z
dc.description.abstractA multivariate version of the classical univariate standard addition method is tested as a proof of concept for the voltammetric analysis of complex samples generating overlapped signals in the presence of significant matrix effects. The proposed strategy applies a multivariate calibration method such as partial least squares (PLS) to the full voltammograms measured for the sample alone and after combined additions of a series of standard solutions (one for every analyte). Then, a calibration model is built and further applied to the prediction of the concentration added to a blank, i.e., a full voltammetric signal measured in the absence of analytes. The absolute value of such predicted concentration is taken as the concentration of the analyte in the sample. The method has been successfully tested in different natural water samples spiked with hydroquinone and catechol and appears to be a promising tool for the analysis of overlapped signals in complex matrices.
dc.format.extent7 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec680447
dc.identifier.issn0169-7439
dc.identifier.urihttps://hdl.handle.net/2445/122531
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.chemolab.2018.05.002
dc.relation.ispartofChemometrics and Intelligent Laboratory Systems, 2018, vol. 178, p. 32-38
dc.relation.urihttps://doi.org/10.1016/j.chemolab.2018.05.002
dc.rightscc-by-nc-nd (c) Elsevier B.V., 2018
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationQuimiometria
dc.subject.classificationVoltametria
dc.subject.otherChemometrics
dc.subject.otherVoltammetry
dc.titleMultivariate standard addition for the analysis of overlapping voltammetric signals in the presence of matrix effects: Application to the simultaneous determination of hydroquinone and catechol
dc.typeinfo:eu-repo/semantics/article