Differential changes in myocardial performance index and its time intervals in donors and recipients of twin-to-twin transfusion syndrome before and after laser therapy.

dc.contributor.authorOrtiz, Javier U.
dc.contributor.authorTorres, Ximena
dc.contributor.authorEixarch Roca, Elisenda
dc.contributor.authorBennasar Sans, Mª del Mar
dc.contributor.authorCruz Lemini, Mónica Cristina
dc.contributor.authorGómez, Olga
dc.contributor.authorLobmaier, Silvia M.
dc.contributor.authorMartínez Crespo, Josep M. (Josep Maria)
dc.contributor.authorGratacós Solsona, Eduard
dc.contributor.authorCrispi Brillas, Fàtima
dc.date.accessioned2018-07-10T17:17:02Z
dc.date.available2018-07-10T17:17:02Z
dc.date.issued2018-01-19
dc.date.updated2018-07-10T17:17:02Z
dc.description.abstractOBJECTIVE: To evaluate left myocardial performance index (MPI) and time intervals in fetuses with twin-to-twin transfusion syndrome (TTTS) before and after laser surgery. METHODS: Fifty-one fetal pairs with TTTS and 47 uncomplicated monochorionic twin pairs were included. Left ventricular isovolumetric contraction time (ICT), ejection time (ET), and isovolumetric relaxation time (IRT) were measured using conventional Doppler. RESULTS: Recipients showed prolonged ICT (46 ± 12 vs. 31 ± 8 vs. 30 ± 5 ms; p < 0.001) and IRT (51 ± 9 vs. 43 ± 8 vs. 43 ± 5 ms; p < 0.001) and higher MPI (0.57 ± 0.12 vs. 0.47 ± 0.09 vs. 0.44 ± 0.05; p < 0.001) than donors and controls. Donors showed shorter ET than recipients and controls (157 ± 12 vs. 169 ± 10 vs. 168 ± 10 ms; p < 0.001) and higher MPI than controls (0.47 ± 0.09 vs. 0.44 ± 0.05; p = 0.006). Preoperative MPI changes were observed in all TTTS stages. Time intervals partially improved after surgery. CONCLUSION: Donor and recipient twins had higher MPI due to different changes in the time intervals, possibly reflecting the state of hypovolemia in the donor and hypervolemia and pressure overload in the recipient.
dc.format.extent15 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec678948
dc.identifier.issn1015-3837
dc.identifier.pmid29353282
dc.identifier.urihttps://hdl.handle.net/2445/123442
dc.language.isoeng
dc.publisherKarger
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1159/000485380
dc.relation.ispartofFetal Diagnosis and Therapy, 2018
dc.relation.urihttps://doi.org/10.1159/000485380
dc.rights(c) Karger, 2018
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
dc.subject.classificationEmbaràs
dc.subject.classificationBessons
dc.subject.classificationLàsers en medicina
dc.subject.otherPregnancy
dc.subject.otherTwins
dc.subject.otherLasers in medicine
dc.titleDifferential changes in myocardial performance index and its time intervals in donors and recipients of twin-to-twin transfusion syndrome before and after laser therapy.
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
678948.pdf
Mida:
336.52 KB
Format:
Adobe Portable Document Format