El CRAI romandrà tancat del 24 de desembre de 2025 al 6 de gener de 2026. La validació de documents es reprendrà a partir del 7 de gener de 2026.
El CRAI permanecerá cerrado del 24 de diciembre de 2025 al 6 de enero de 2026. La validación de documentos se reanudará a partir del 7 de enero de 2026.
From 2025-12-24 to 2026-01-06, the CRAI remain closed and the documents will be validated from 2026-01-07.
 

Preventing false negatives with high-resolution mass spectrometry: the benzophenone case

dc.contributor.authorGallart Ayala, Hèctor
dc.contributor.authorNúñez Burcio, Oscar
dc.contributor.authorMoyano Morcillo, Encarnación
dc.contributor.authorGalcerán Huguet, M. Teresa
dc.contributor.authorMartins, Cláudia P. B.
dc.date.accessioned2016-05-03T09:56:29Z
dc.date.available2016-05-03T09:56:29Z
dc.date.issued2011-09-13
dc.date.updated2016-05-03T09:56:34Z
dc.description.abstractBenzophenone (BP) is one of the many contaminants reported as present in foodstuff due to its migration from food packaging materials. Liquid chromatography tandem mass spectrometry (LC-MS/MS) is acknowledged in the literature as the method of choice for this analysis. However, cases have been reported where the use of this methodology was not enough to unambiguously confirm the presence of a contaminant. In previous work performed by the authors, the unequivocal identification of BP in packaged foods was not possible even when monitoring two m/z transitions, since ion ratio errors higher than 20% were obtained. In order to overcome this analytical problem a fast, sensitive and selective liquid chromatography-high resolution-mass spectrometry (LC-HRMS) methodology has been developed and applied to the analysis of BP in packaged foods. A direct comparison between liquid chromatography high resolution mass spectrometry (LC-HRMS) and LC-MS/MS data indicated better selectivity when working with LC-HRMS at a resolving power of 50,000 FWHM than when monitoring two m/z transitions by LC-MS/MS. The resolving power used enabled the detection and identification of Harman as the compound impeding the confirmation of BP by LC-MS/MS. Similar quantitative results were obtained by an Orbitrap mass analyser (Exactive ¿) and a triple quadrupole mass analyser (TSQ Quantum Ultra AM ¿).
dc.format.extent19 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec598809
dc.identifier.issn0951-4198
dc.identifier.pmid21953972
dc.identifier.urihttps://hdl.handle.net/2445/98200
dc.language.isoeng
dc.publisherWiley
dc.relation.isformatofVersió postprint del document publicat a: http://dx.doi.org/10.1002/rcm.5200
dc.relation.ispartofRapid Communications in Mass Spectrometry, 2011, vol. 25, num. 20, p. 3161-3166
dc.relation.urihttp://dx.doi.org/10.1002/rcm.5200
dc.rights(c) Wiley, 2011
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationEspectrometria de masses
dc.subject.classificationCromatografia
dc.subject.classificationEnvasament d'aliments
dc.subject.classificationQuímica dels aliments
dc.subject.otherMass spectrometry
dc.subject.otherChromatography
dc.subject.otherFood packaging
dc.subject.otherFood composition
dc.titlePreventing false negatives with high-resolution mass spectrometry: the benzophenone case
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
598809.pdf
Mida:
309.71 KB
Format:
Adobe Portable Document Format