Evaluation of Hold-Up Volume Determination Methods and Markers in Hydrophilic Interaction Liquid Chromatograph

dc.contributor.authorRedón, Lídia
dc.contributor.authorSubirats i Vila, Xavier
dc.contributor.authorRosés Pascual, Martí
dc.date.accessioned2023-03-03T16:07:22Z
dc.date.available2023-03-03T16:07:22Z
dc.date.issued2023-02-01
dc.date.updated2023-03-03T16:07:22Z
dc.description.abstractCommon methods for hold-up time and volume determination in Reversed-Phase Liquid Chromatography (RPLC) have been tested for Hydrophilic Interaction Liquid Chromatography (HILIC). A zwitterionic ZIC-HILIC column has been used for the testing. The pycnometric determination method, based on differences in column weight when filled with water or organic solvent, provides the overall volume of solvent inside the column. This includes the volume of eluent semi-sorbed on the packing of the column, which acts as the main stationary phase. The homologous series approach, based on the retention behavior of homologues in relation to their molecular volume, allows the determination of accurate hold-up volumes. However, the application of this method is time-consuming. In some cases, large neutral markers with poor dipolarity/polarizability and hydrogen bonding interactions can be used as hold-up volume markers. This is the case of dodecylbenzene and nonadecane-2-one in clearly HILIC behaving chromatographic systems, the use of decanophenone as a marker can be even extended to the boundary between HILIC and RPLC. The elution volume of the marker remains nearly unaffected by the concentration of ammonium acetate in the mobile phase up to 20 mM. The injection of pure solvents to produce minor base-line disturbance as hold-up markers is strongly discouraged, since solvent peaks are complex to interpret and depend on the ionic strength of the eluent.
dc.format.extent16 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec728874
dc.identifier.issn1420-3049
dc.identifier.urihttps://hdl.handle.net/2445/194593
dc.language.isoeng
dc.publisherMDPI
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/molecules28031372
dc.relation.ispartofMolecules, 2023, vol. 28, num. 3, p. 1372
dc.relation.urihttps://doi.org/10.3390/molecules28031372
dc.rightscc-by (c) Redón, Lídia et al., 2023
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationCromatografia de líquids
dc.subject.classificationDinàmica de fluids
dc.subject.otherLiquid chromatography
dc.subject.otherFluid dynamics
dc.titleEvaluation of Hold-Up Volume Determination Methods and Markers in Hydrophilic Interaction Liquid Chromatograph
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
728874.pdf
Mida:
2.23 MB
Format:
Adobe Portable Document Format