Measuring depression in primary health care in Spain: psychometric properties and diagnostic accuracy of HSCL-5 and HSCL-10

dc.contributor.authorRodríguez-Barragán, María
dc.contributor.authorFernández-San-Martín, María Isabel
dc.contributor.authorClavería-Fontán, Ana
dc.contributor.authorNabbe, Patrice
dc.contributor.authorMotrico, Emma
dc.contributor.authorGómez-Gómez, Irene
dc.contributor.authorPeguero Rodríguez, Eva
dc.contributor.authorLe Reste, Jean Yves
dc.date.accessioned2025-03-17T16:29:23Z
dc.date.available2025-03-17T16:29:23Z
dc.date.issued2023-01-09
dc.date.updated2025-03-17T16:29:23Z
dc.description.abstractBackground: Depression has a high prevalence among European countries. Several instruments have been designed to assess its symptoms in different populations. The Hopkins Symptom Checklist 25 (HSCL-25) scale has been identified as valid, reproducible, effective, and easy to use. There are short versions of this scale that could be useful in Primary Care (PC) settings, but their psychometric properties are unknown. Aim: To assess in PC patients the psychometric properties and diagnostic accuracy of the Spanish version of the HSCL-10 and the HSCL-5 consisting of 10 and 5 items, respectively. Methods: A multicenter, cross-sectional study was carried out at six PC centers in Spain. The HSCL-25 was administered to outpatients aged 45-75 who also participated in the structured Composite International Diagnostic Interview (CIDI). HSCL-10 and HSCL-5 were assessed and compared to HSCL-25 regarding total score correlation, internal consistency, and criterion validity against the gold-standard CIDI. This is a methodological study from a secondary data analysis and the primary data has been previously published. Results: Out of 790 patients, 767 completed the HSCL-25 and 736 the CIDI interview (96.0%). Cronbach's Alpha was 0.84 for HSCL-10 and 0.77 for HSCL-5. The known-group method and confirmatory factor analysis were acceptable for the establishment of construct validity. Sensitivity was 79.7% (CI95%, 67.7-88.0%) for HSCL-10, and 78.0% (CI95%, 65.9-86.6%) for HSCL-5, whereas specificity was 83% (CI95%, 80.0-85.7%) for HSCL-10, and 72.8% (CI95%, 69.3-76.0%) for HSCL-5. Area under the curve against CIDI was 0.88 (CI95%, 0.84-0.92%) for HSCL-10, and 0.85 (CI95%, 0.81-0.89%) for HSCL-5. Optimum cutoff point calculated with Youden Index was 1.90 for the HSCL-10 and 1.80 for the HSCL-5. Conclusion: HSCL-10 and HSCL-5 are reliable and valid tools to detect depression symptoms and can be used in PC settings.
dc.format.extent13 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec740772
dc.identifier.issn2296-858X
dc.identifier.pmid36698836
dc.identifier.urihttps://hdl.handle.net/2445/219788
dc.language.isoeng
dc.publisherFrontiers Media
dc.relation.isformatofReproducció del document publicat a: https://doi.org/DOI: 10.3389/fmed.2022.1014340
dc.relation.ispartofFrontiers in Medicine, 2023, vol. 9, num.2023
dc.relation.urihttps://doi.org/DOI: 10.3389/fmed.2022.1014340
dc.rightscc-by (c) Rodríguez-Barragán, María et al., 2023
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceArticles publicats en revistes (Ciències Clíniques)
dc.subject.classificationAtenció primària
dc.subject.classificationPsicometria
dc.subject.classificationDepressió psíquica
dc.subject.otherPrimary care
dc.subject.otherPsychometrics
dc.subject.otherMental depression
dc.titleMeasuring depression in primary health care in Spain: psychometric properties and diagnostic accuracy of HSCL-5 and HSCL-10
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
836601.pdf
Mida:
662.87 KB
Format:
Adobe Portable Document Format