Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Tipus de document

Article

Versió

Versió acceptada

Data de publicació

Tots els drets reservats

Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/227112

Vascular surgery study of the CGuard MicroNet-covered stent in patients with indication to carotid revascularization: POLGUARD

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

BACKGROUND: In a recent randomized study, MicroNet-covered stent (CGuard) significantly reduced procedural and post-procedural cerebral embolism in relation to a single-layer CREST study carotid stent, but real-life clinical practice data are limited. The aim is to prospectively assess clinical outcomes of CGuard as a routine revascularization tool for patients with indication to carotid revascularization. METHODS: From April 2019 to November 2021, 204 elective patients (age 71.0±7.1years, 69.6% males, 21.7% symptomatic) were enrolled. RESULTS: Mean basal peak-systolic velocity was 251.41±91.85 cm/s with angiographic diameter stenosis 89.7±8.46%. About 34.4% lesions were severely calcified, 6.8% were angulated, and 4.4% showed significant access tortuosity. Access was femoral, with 100% protection device (filter) use. Two hundred and three lesions in 203 patients were treated (1 cross-over to surgery for lack of effective access, no cross-over to other devices); in most cases (66.9%) the stent was placed directly. For pre-dilated lesions, mean balloon diameter was 3.36±0.34mm. Mean nominal stent diameter was 7.64±0.5 mm; length was 37.19±4.5 mm. All stents were post-dilated (balloon diameter 5.2±0.25 mm). Residual stenosis was <30% in all (3.77±6.91%). By discharge, there were 2 minor strokes (0.9%) and one transient ischemic attack. By 30-days, one other minor stroke occurred in relation to de-novo atrial fibrillation. With no deaths or myocardial infarctions, 30-day total death/stroke/myocardial infarction rate was 1.48%. No in-stent thrombosis or patency loss occurred by 30-days. In-stent peak-systolic velocity was 55.49±22.73 cm/s. CONCLUSIONS: Thirty-day results from POLGUARD study indicate safety and a low complication rate of the MicroNet-covered carotid stent use in every-day vascular surgery practice of carotid revascularization. Long-term observation is underway.

Citació

Citació

BEDKOWSKI, Lukasz, et al. Vascular surgery study of the CGuard MicroNet-covered stent in patients with indication to carotid revascularization: POLGUARD. Journal of Cardiovascular Surgery. 2023. Vol. 64, num. 6, pags. 615-623. ISSN 0021-9509. [consulted: 4 of August of 2026]. Available at: https://hdl.handle.net/2445/227112

Exportar metadades

JSON - METS

Compartir registre