Computed digital absorptiometry of the hand: screening method of bone loss in postmenopausal women with RA.

dc.contributor.authorNolla Solé, Joan Miquelcat
dc.contributor.authorGómez Vaquero, Carmencat
dc.contributor.authorFiter, Jordicat
dc.contributor.authorRoig Escofet, D. (Daniel)cat
dc.dateDual energy x ray absorptiometry (DXA) is the most commonly used method of measuring bone mineral density (BMD); it has been shown to be a good predictor of the future risk of fracture.1Unfortunately, the generalised use of DXA is limited as it is expensive and time consuming, is not portable, and is available only in specialised clinics.#N##N#Computed digital absorptiometry (CDA) of the hand is a new bone densitometry technique, designed to assess the BMD of the middle phalanx of the third finger using a direct, automated measurement of x ray attenuation.2This technique is similar to radiographic absorptiometry but provides immediate results; in current radiographic absorptiometry, radiographs are sent to an off site processing centre and the results are received a few days later. CDA is cheap and quick. Its precision and accuracy seem to be acceptable, but its ability to discriminate between patients with osteoporosis and normal subjects, to predict risk of …
dc.date.accessioned2012-03-05T12:52:33Z
dc.date.available2012-03-05T12:52:33Z
dc.date.issued2000ca
dc.description.abstractDual energy x ray absorptiometry (DXA) is the most commonly used method of measuring bone mineral density (BMD); it has been shown to be a good predictor of the future risk of fracture.1Unfortunately, the generalised use of DXA is limited as it is expensive and time consuming, is not portable, and is available only in specialised clinics.#N##N#Computed digital absorptiometry (CDA) of the hand is a new bone densitometry technique, designed to assess the BMD of the middle phalanx of the third finger using a direct, automated measurement of x ray attenuation.2This technique is similar to radiographic absorptiometry but provides immediate results; in current radiographic absorptiometry, radiographs are sent to an off site processing centre and the results are received a few days later. CDA is cheap and quick. Its precision and accuracy seem to be acceptable, but its ability to discriminate between patients with osteoporosis and normal subjects, to predict risk of …
dc.format.extent1 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec535337ca
dc.identifier.issn0003-4967ca
dc.identifier.pmid10885977
dc.identifier.urihttps://hdl.handle.net/2445/22472
dc.language.isoengeng
dc.publisherBMJ Group
dc.relation.isformatofReproducció digital del document publicat a: http://dx.doi.org/10.1136/ard.59.6.490b
dc.relation.ispartofAnnals of the Rheumatic Diseases, 2000, vol. 59, núm. 6, p. 492
dc.relation.urihttp://dx.doi.org/10.1136/ard.59.6.490b
dc.rights(c) BMJ Publishing Group Ltd, 2000
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Ciències Clíniques)
dc.subject.classificationDensitometria òssiacat
dc.subject.classificationArtritis reumatoidecat
dc.subject.classificationMenopausacat
dc.subject.otherBone densitometryeng
dc.subject.otherRheumatoid arthritiseng
dc.subject.otherMenopauseeng
dc.titleComputed digital absorptiometry of the hand: screening method of bone loss in postmenopausal women with RA.eng
dc.typeinfo:eu-repo/semantics/article