Carregant...
Miniatura

Tipus de document

Article

Versió

Versió publicada

Data de publicació

Llicència de publicació

cc-by (c) Noorian, Faegheh et al., 2023
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/217423

Are 7.5Gy×2 fractions more efficient than 6Gy×3 in exclusive postoperative endometrial cancer brachytherapy? a clinical and dosimetrical analysis

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

To compare two vaginal brachytherapy (VBT) schedules in postoperative endometrial carcinoma (PEC) patients considering vaginal-cuff relapses (VCR), late toxicities, dosimetry analysis and vaginal dilator use. Material and methods: 110 PEC patients were treated with exclusive high-dose-rate VBT using two schedules. Group-1:44-patients received 6 Gy×3fractions (September-2011-April-2014); Group-2:66-patients were treated with 7.5 Gy×2fractions with a dose limit of equivalent total doses in 2-Gy fr (EQD2(α/β=3)) of 68 Gy in the most exposed 2 cm3 of clinical target volume (CTV) (July-2015-November-2021). The dose was prescribed at 5 mm from the applicator surface. Were evaluated the overall radiation dose delivered to 90% of the CTV (D90), the CTV receiving 100% of the prescription dose (V100) and the EQD2(α/β=3) received in the most exposed 2 cm3 to dose in CTV. Late toxicity was prospectively assessed using RTOG scores for bladder and rectum and objective LENT-SOMA criteria for late vaginal toxicity (LVT). Statistics: Descriptive analysis, Chi-square, Student's t-tests and Kaplan and Meier method. Results: The median follow-up was 60 months (15.9-60). There were no VCR or late toxicities in bladder or rectum. LVT ≥ G1 appeared in 26/44 (59.1%) in Group-1 and 25/66 (37.9%) in Group-2. The mean EQD2(α/β=3) received by the most exposed 2 cm3 of CTV was 63.7 Gy ± 10.0 in Group-1 and 60.5 Gy ± 3.8 in Group-2 (p = 0.063). There were no differences in adherence to vaginal dilator use ≥9 months, overall D90 and V100. Conclusion: Considering the lack of vaginal relapses and similar LVT over time, 7.5 Gy×2fractions seem more efficient in terms of patient comfort, workload, and cost. This is the first study using dosimetry parameters to compare effectivity of schedules. Larger series are needed to confirm the present results.

Citació

Citació

NOORIAN, Faegheh, ABELLANA SANGRÀ, Rosa mari, ZHANG, Yaowen, HERREROS, Antonio, BALTRONS, Clara, LANCELLOTTA, Valentina, TAGLIAFERRI, Luca, SABATER, Sebastià, TORNE, Aureli, ROVIROSA CASINO, Angeles. Are 7.5Gy×2 fractions more efficient than 6Gy×3 in exclusive postoperative endometrial cancer brachytherapy? a clinical and dosimetrical analysis. _Radiotherapy and Oncology_. 2023. Vol. 189. [consulta: 13 de gener de 2026]. ISSN: 0167-8140. [Disponible a: https://hdl.handle.net/2445/217423]

Exportar metadades

JSON - METS

Compartir registre