Improved image quality in pinhole SPECT by accurate modeling of the point spread function in low magnification systems

dc.contributor.authorPino Sorroche, Francisco
dc.contributor.authorRoé Vellvé, Nuria
dc.contributor.authorAguiar, Pablo
dc.contributor.authorFalcon, Carles
dc.contributor.authorRos Puig, Domènec
dc.contributor.authorPavía Segura, Javier
dc.date.accessioned2017-01-25T15:25:03Z
dc.date.available2017-01-25T15:25:03Z
dc.date.issued2015-02
dc.date.updated2017-01-25T15:25:03Z
dc.description.abstractIt is well-known that in pinhole SPECT (single-photon-emission computed tomography), iterative reconstruction methods including accurate estimations of the system response matrix can lead to submillimeter spatial resolution. There are two different methods for obtaining the system response matrix: those that model the system analytically using an approach including an experimental characterization of the detector response, and those that make use of Monte Carlo simulations. Methods based on analytical approaches are faster and handle the statistical noise better than those based on Monte Carlo simulations, but they require tedious experimental measurements of the detector response. One suggested approach for avoiding an experimental characterization, circumventing the problem of statistical noise introduced by Monte Carlo simulations, is to perform an analytical computation of the system response matrix combined with a Monte Carlo characterization of the detector response. Our findings showed that this approach can achieve high spatial resolution similar to that obtained when the system response matrix computation includes an experimental characterization. Furthermore, we have shown that using simulated detector responses has the advantage of yielding a precise estimate of the shift between the point of entry of the photon beam into the detector and the point of interaction inside the detector. Considering this, it was possible to slightly improve the spatial resolution in the edge of the field of view.
dc.format.extent12 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec649408
dc.identifier.issn0094-2405
dc.identifier.pmid25652484
dc.identifier.urihttps://hdl.handle.net/2445/106082
dc.language.isoeng
dc.publisherAmerican Association of Physicists in Medicine
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1118/1.4905157
dc.relation.ispartofMedical Physics, 2015, vol. 42, num. 2, p. 703-714
dc.relation.urihttps://doi.org/10.1118/1.4905157
dc.rights(c) American Association of Physicists in Medicine, 2015
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Biomedicina)
dc.subject.classificationTomografia computada per emissió de fotó simple
dc.subject.classificationProcessament d'imatges
dc.subject.classificationTomografia
dc.subject.otherSingle-photon emission computed tomography
dc.subject.otherImage processing
dc.subject.otherTomography
dc.titleImproved image quality in pinhole SPECT by accurate modeling of the point spread function in low magnification systems
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
649408.pdf
Mida:
2.04 MB
Format:
Adobe Portable Document Format