HILIC characterization: estimation of phase volumes and composition for a zwitterionic column

dc.contributor.authorRedón, Lídia
dc.contributor.authorSubirats i Vila, Xavier
dc.contributor.authorRosés Pascual, Martí
dc.date.accessioned2020-09-02T09:03:32Z
dc.date.available2021-07-08T05:10:19Z
dc.date.issued2020-07-08
dc.date.updated2020-09-02T09:03:32Z
dc.description.abstractA methodology for the estimation of the different phase volumes in HILIC is presented. For a ZIC-HILIC column the mobile phase volume (hold-up volume) is determined in several acetonitrile- and methanol-water compositions by a Linear Free Energy Relationships (LFER) homologous series approach involving n-alkyl-benzenes, -phenones, and -ketones. We demonstrate that the column works as a HILIC column when the mobile phase contains high and medium proportions of methanol or acetonitrile. However, for acetonitrile contents below 20%, or 40% for methanol, same column works in RPLC. In between, a mixed HILIC-RPLC behavior is observed, and solutes of low molecular volume are retained as in HILIC mode, but the largest ones show RPLC retention. From the homologous series retention data and pycnometric measurements involving the pure organic solvents and their mixtures with water, the mean solvent composition of the water-rich transition layers between column functionalization and the bulk mobile phase, which act as stationary phase, is estimated. Finally, the phase ratio between stationary and mobile phases is also estimated for each eluent composition, allowing the calculation of the corresponding stationary phase volumes. All volumes are strongly dependent on the water content in the eluent, especially when acetonitrile is selected as mobile phase constituent. In HILIC mode, when the water content in the hydroorganic mobile phase increases, the volumes of mobile phase decrease, but the volumes of stationary phase (mainly the water layer adsorbed onto the bonded-phase and the water-enriched interface) increase. However, at high water concentrations, where the column works in RPLC mode, the mobile phase volume increases and the stationary phase (which is now the bonded zwitterion) volume decreases when increasing the water percentage in the mobile phase.
dc.format.extent10 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec702652
dc.identifier.issn0003-2670
dc.identifier.urihttps://hdl.handle.net/2445/170094
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.aca.2020.06.035
dc.relation.ispartofAnalytica Chimica Acta, 2020, vol. 1130, p. 39-48
dc.relation.urihttps://doi.org/10.1016/j.aca.2020.06.035
dc.rightscc-by-nc-nd (c) Elsevier B.V., 2020
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationCromatografia de líquids
dc.subject.classificationDinàmica de fluids
dc.subject.otherLiquid chromatography
dc.subject.otherFluid dynamics
dc.titleHILIC characterization: estimation of phase volumes and composition for a zwitterionic column
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion