Selenocystine modified screen-printed electrode as an alternative sensor for the voltammetric determination of metal ions
| dc.contributor.author | Puy, Jaume | |
| dc.contributor.author | Pérez Ràfols, Clara | |
| dc.contributor.author | Serrano i Plana, Núria | |
| dc.contributor.author | Díaz Cruz, José Manuel | |
| dc.contributor.author | Ariño Blasco, Cristina | |
| dc.contributor.author | Esteban i Cortada, Miquel | |
| dc.date.accessioned | 2019-01-29T18:08:12Z | |
| dc.date.available | 2019-07-29T05:10:18Z | |
| dc.date.issued | 2017-07-29 | |
| dc.date.updated | 2019-01-29T18:08:12Z | |
| dc.description.abstract | A novel selenium based screen-printed electrode was developed based on the immobilization of selenocystine on aryl diazonium salt monolayers anchored to a carbon-nanofiber screen-printed electrode support (SeCyst- SPCNFE). SeCyst-SPCNFE was analytically compared to a screen-printed carbon nanofiber electrode modified with L-Cystine (Cyst-SPCNFE) for the determination of Pb(II) and Cd(II) by stripping voltammetric techniques. Their analytical performance suggests that SeCyst-SPCNFE could be a much better alternative for metal ion determination at trace levels than Cyst-SPCNFE. The proposed electrode was successfully applied for the simultaneous voltammetric determination of trace Pb(II) and Cd(II) in a wastewater reference material with a very high reproducibility (3.2%) and good trueness (2.6%). | |
| dc.format.extent | 6 p. | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.idgrec | 673186 | |
| dc.identifier.issn | 0039-9140 | |
| dc.identifier.pmid | 28842024 | |
| dc.identifier.uri | https://hdl.handle.net/2445/127716 | |
| dc.language.iso | eng | |
| dc.publisher | Elsevier B.V. | |
| dc.relation.isformatof | Versió postprint del document publicat a: https://doi.org/10.1016/j.talanta.2017.07.089 | |
| dc.relation.ispartof | Talanta, 2017, vol. 175, p. 501-506 | |
| dc.relation.uri | https://doi.org/10.1016/j.talanta.2017.07.089 | |
| dc.rights | cc-by-nc-nd (c) Elsevier B.V., 2017 | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es | |
| dc.source | Articles publicats en revistes (Enginyeria Química i Química Analítica) | |
| dc.subject.classification | Voltametria | |
| dc.subject.classification | Elèctrodes | |
| dc.subject.classification | Seleni | |
| dc.subject.other | Voltammetry | |
| dc.subject.other | Electrodes | |
| dc.subject.other | Selenium | |
| dc.title | Selenocystine modified screen-printed electrode as an alternative sensor for the voltammetric determination of metal ions | |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:eu-repo/semantics/acceptedVersion |