Selenocystine modified screen-printed electrode as an alternative sensor for the voltammetric determination of metal ions

dc.contributor.authorPuy, Jaume
dc.contributor.authorPérez Ràfols, Clara
dc.contributor.authorSerrano i Plana, Núria
dc.contributor.authorDíaz Cruz, José Manuel
dc.contributor.authorAriño Blasco, Cristina
dc.contributor.authorEsteban i Cortada, Miquel
dc.date.accessioned2019-01-29T18:08:12Z
dc.date.available2019-07-29T05:10:18Z
dc.date.issued2017-07-29
dc.date.updated2019-01-29T18:08:12Z
dc.description.abstractA novel selenium based screen-printed electrode was developed based on the immobilization of selenocystine on aryl diazonium salt monolayers anchored to a carbon-nanofiber screen-printed electrode support (SeCyst- SPCNFE). SeCyst-SPCNFE was analytically compared to a screen-printed carbon nanofiber electrode modified with L-Cystine (Cyst-SPCNFE) for the determination of Pb(II) and Cd(II) by stripping voltammetric techniques. Their analytical performance suggests that SeCyst-SPCNFE could be a much better alternative for metal ion determination at trace levels than Cyst-SPCNFE. The proposed electrode was successfully applied for the simultaneous voltammetric determination of trace Pb(II) and Cd(II) in a wastewater reference material with a very high reproducibility (3.2%) and good trueness (2.6%).
dc.format.extent6 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec673186
dc.identifier.issn0039-9140
dc.identifier.pmid28842024
dc.identifier.urihttps://hdl.handle.net/2445/127716
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.talanta.2017.07.089
dc.relation.ispartofTalanta, 2017, vol. 175, p. 501-506
dc.relation.urihttps://doi.org/10.1016/j.talanta.2017.07.089
dc.rightscc-by-nc-nd (c) Elsevier B.V., 2017
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationVoltametria
dc.subject.classificationElèctrodes
dc.subject.classificationSeleni
dc.subject.otherVoltammetry
dc.subject.otherElectrodes
dc.subject.otherSelenium
dc.titleSelenocystine modified screen-printed electrode as an alternative sensor for the voltammetric determination of metal ions
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
673186.pdf
Mida:
1.1 MB
Format:
Adobe Portable Document Format