Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Non-rigid alignment pipeline applied to human gait signals acquired with optical motion capture systems and inertial sensors

dc.contributor.authorSoussé, Rubén
dc.contributor.authorVerdú, Jorge
dc.contributor.authorJauregui, Ricardo
dc.contributor.authorFerrer-Roca, Ventura
dc.contributor.authorBalocco, Simone
dc.date.accessioned2023-02-09T09:36:57Z
dc.date.available2023-02-09T09:36:57Z
dc.date.issued2020-01-02
dc.date.updated2023-02-09T09:36:57Z
dc.description.abstractAn accurate gait characterization is fundamental for diagnosis and treatment in both clinical and sportive fields. Although several devices allow such measurements, the performance comparison between the acquired signals may be a challenging task. A novel pipeline for the accurate non-rigid alignment of gait signals is proposed. In this paper, the measurements of Inertial Measurement Units (IMU) and Optical Motion Capture Systems (OMCAP) are aligned using a modified version of the Dynamic Time Warping (DTW) algorithm. The differences between the two acquisitions are evaluated using both global (RMSE, Correlation Coefficient (CC)) and local (Statistical Parametric Mapping (SPM)) metrics. The method is applied to a data-set obtained measuring the gait of ten healthy subjects walking on a treadmill at three different gait paces. Results show a global bias between the signal acquisition of 0.05°. Regarding the global metrics, a mean RMSE value of 2.65° (0.73°) and an average CC value of 0.99 (0.01) were obtained. The SPM profile shows, in each gait cycle phase, the percentage of cases when two curves are statistically identical and reaches an average of 48% (22%).
dc.format.extent17 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec692985
dc.identifier.issn0021-9290
dc.identifier.urihttps://hdl.handle.net/2445/193323
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.jbiomech.2019.109429
dc.relation.ispartofJournal of Biomechanics, 2020, vol. 98
dc.relation.urihttps://doi.org/10.1016/j.jbiomech.2019.109429
dc.rightscc-by-nc-nd (c) Elsevier B.V., 2020
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceArticles publicats en revistes (Matemàtiques i Informàtica)
dc.subject.classificationCinemàtica
dc.subject.classificationOptoelectrònica
dc.subject.classificationAlgorismes computacionals
dc.subject.otherKinematics
dc.subject.otherOptoelectronics
dc.subject.otherComputer algorithms
dc.titleNon-rigid alignment pipeline applied to human gait signals acquired with optical motion capture systems and inertial sensors
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
692985.pdf
Mida:
650.29 KB
Format:
Adobe Portable Document Format