Carregant...
Tipus de document
Treball de fi de grauData de publicació
Llicència de publicació
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/102933
On the study of wavefront aberrations combining a point-diffraction interferometer and a Shack-Hartmann sensor
Títol de la revista
Autors
Director/Tutor
ISSN de la revista
Títol del volum
Recurs relacionat
Resum
A comparison between reconstruction of wavefront aberration (WA) provided by two different techniques (a point-diffraction interferometer and a Shack-Hartmann wavefront sensor) applied on the study of a meniscus lens is presented. The description of WA is done in terms of the Zernike polynomials and, when terms up to 4th order of the expansion are taken, the maximum difference of the root-mean-square (RMS) between both techniques is reduced to 0.08 𝜇𝑚, excluding pseudo-aberration terms
Descripció
Treballs Finals de Grau de Física, Facultat de Física, Universitat de Barcelona, Curs: 2016, Tutor: Santiago Vallmitjana
Matèries
Matèries (anglès)
Citació
Col·leccions
Citació
MARZOA DOMÍNGUEZ, Antonio. On the study of wavefront aberrations combining a point-diffraction interferometer and a Shack-Hartmann sensor. [consulta: 25 de febrer de 2026]. [Disponible a: https://hdl.handle.net/2445/102933]