Document type
Bachelor thesisPublication date
Publication license
Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/102933
On the study of wavefront aberrations combining a point-diffraction interferometer and a Shack-Hartmann sensor
Journal Title
Authors
Director/Tutor
Additional contribution
Journal ISSN
Volume Title
Abstract
A comparison between reconstruction of wavefront aberration (WA) provided by two different techniques (a point-diffraction interferometer and a Shack-Hartmann wavefront sensor) applied on the study of a meniscus lens is presented. The description of WA is done in terms of the Zernike polynomials and, when terms up to 4th order of the expansion are taken, the maximum difference of the root-mean-square (RMS) between both techniques is reduced to 0.08 𝜇𝑚, excluding pseudo-aberration terms
Description
Treballs Finals de Grau de Física, Facultat de Física, Universitat de Barcelona, Curs: 2016, Tutor: Santiago Vallmitjana
Related resource
Subject
Subject (English)
Citation
Collections
Citation
MARZOA DOMÍNGUEZ, Antonio. On the study of wavefront aberrations combining a point-diffraction interferometer and a Shack-Hartmann sensor. [consulted: 6 of October of 2026]. Available at: https://hdl.handle.net/2445/102933