Impact of acquisition parameters on diffusion magnetic resonance imaging quality

dc.contributor.advisorPascual-Diaz, Saül
dc.contributor.advisorPrats Galino, Alberto
dc.contributor.authorGómez Fernández, Marina
dc.date.accessioned2022-06-21T10:36:10Z
dc.date.available2022-06-21T10:36:10Z
dc.date.issued2022-06
dc.descriptionTreballs Finals de Grau d'Enginyeria Biomèdica. Facultat de Medicina i Ciències de la Salut. Universitat de Barcelona. Curs: 2021-2022. Director: Saül Pascual-Díaz i Tutor: Alberto Prats Galinoca
dc.description.abstractAcquisition parameters play a crucial role in Diffusion Tensor Imaging (DTI), having such an impact on white matter (WM) scalar measures values such as Fractional Anisotropy (FA), Signal to Noise Ratio (SNR) or even when it comes to whole brain tractography studies. Among those acquisitions parameters we find the b-values (e.g. b-value is a factor that reflects the strength and timing of those gradients used to generate Diffusion-Weighted Images; the higher the b-value, the stronger the diffusion effects), voxel size (the smaller the voxel size the higher the quality) and diffusion directions (as the number of directions increases the acquisition time increases as well). This project, places all of them of the focus of several clinical MRI studies performed on healthy subjects in the IDIBAPS’ MRI core facility. Those studies have been grouped into 5 datasets according to different acquisition protocols; in addition, 8 new acquisition proposal are first undergone and analysed. Results show that as expected those parameters play a crucial role in image quality; however, each one of them has a different weight over those quality measurements. This will be discussed by splitting the results into datasets. Furthermore, the analysis performed on the protocol proposals confirm that they have reached what was their goal, to demonstrate that depending on the purpose of the scanner (emergency MRI, clinical MRI and research MRI) a specifical acquisition sequence can be used.ca
dc.format.extent79 p.
dc.format.mimetypeapplication/pdf
dc.identifier.urihttps://hdl.handle.net/2445/186819
dc.language.isoengca
dc.rightscc-by-nc-nd (c) Gómez Fernández, Marina, 2022
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessca
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.sourceTreballs Finals de Grau (TFG) - Enginyeria Biomèdica
dc.subject.classificationEnginyeria biomèdica
dc.subject.classificationImatges per ressonància magnètica
dc.subject.classificationTreballs de fi de grau
dc.subject.otherBiomedical engineering
dc.subject.otherMagnetic resonance imaging
dc.subject.otherBachelor's theses
dc.titleImpact of acquisition parameters on diffusion magnetic resonance imaging qualityca
dc.typeinfo:eu-repo/semantics/bachelorThesisca

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
TFG _BE_Marina_Gomez_Fernandez.pdf
Mida:
4.86 MB
Format:
Adobe Portable Document Format
Descripció: