Carregant...
Miniatura

Tipus de document

Article

Versió

Versió publicada

Data de publicació

Llicència de publicació

cc-by (c)  Mariscal-Castilla et al., 2024
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/222115

Toward Sub-100 ps TOF-PET Systems Employing the FastIC ASIC With Analog SiPMs

Títol de la revista

ISSN de la revista

Títol del volum

Resum

Time of Flight positron emission tomography (TOFPET) scanners demand electronics that are power-efficient, low-noise, cost-effective, and possess a large bandwidth. Recent developments have demonstrated sub-100 ps time resolution with elevated power consumption per channel, rendering this unfeasible to build a scanner. In this work, we evaluate the performance for the TOF-PET of the FastIC front-end using different scintillators and silicon photomultipliers (SiPMs). FastIC is an eight-channel application specific integrated circuit developed in CMOS 65 nm capable of measuring the energy and the arrival time of a detected pulse with 12 mW per channel. Using Hamamatsu SiPMs (S13360-3050PE) coupled to LSO:Ce:0.2%Ca crystals of 2 × 2 × 3 mm3 and LYSO:Ce:0.2%Ca of 3.13 × 3.13 × 20 mm3, we measured a coincidence time resolution (CTR) of (95 ± 3) and 156 ± 4) ps full width half maximum (FWHM), respectively. With Fondazione Bruno Kessler NUV-HD LF2 M0 SiPMs coupled to the same crystals, we obtained a CTR of (76 ± 2) and (127 ± 3) ps FWHM. We employed FastIC with a TlCl pure Cherenkov emitter, demonstrating time resolutions comparable to those achieved with the high-power-consuming electronics. These findings shows that the FastIC represents a cost-effective alternative that can significantly enhance the time resolution of the current TOF-PET systems while maintaining low power consumption. Index Terms—Fast front-end electronics, photo-detector technology, positron emission tomography, scintillator, silicon photomultipliers (SiPMs), Time of Flight positron emission tomography (TOF-PET).

Descripció

Citació

Citació

MARISCAL-CASTILLA, Antonio, GOMEZ FERNANDEZ, Sergio, MANERA ESCALERO, Rafel, FERNANDEZ-TENLLADO, José maría, MAURICIO FERRE, Joan, KRATOCHWIL, Nicolaus, ALOZY, J., PILLER, Markus, PORTERO, Sara, SANUY CHARLES, Andreu, GUBERMAN, Daniel, SILVA, J. j., AUFFRAY, Etiennette, BALLABRIGA, Rafael, ARIÑO ESTRADA, Gerard, CAMPBELL, Michael, GASCÓN FORA, David. Toward Sub-100 ps TOF-PET Systems Employing the FastIC ASIC With Analog SiPMs. _IEEE Transactions on Radiation and Plasma Medical Sciences_. 2024. Vol. 8, núm. 7, pàgs. 718-733. [consulta: 25 de novembre de 2025]. ISSN: 2469-7311. [Disponible a: https://hdl.handle.net/2445/222115]

Exportar metadades

JSON - METS

Compartir registre