Electrochemical sensor based on glassy carbon electrode modified with carbon nanohorns (SWCNH) for determination of Cr(VI) via adsorptive cathodic stripping voltammetry (AdCSV) in tap water

dc.contributor.authorLiendo, F.
dc.contributor.authorBryan Pichún, B.
dc.contributor.authorPaz de la Vega, A.
dc.contributor.authorPenagos, J.
dc.contributor.authorSerrano i Plana, Núria
dc.contributor.authorDíaz Cruz, José Manuel
dc.contributor.authorPizarro, J.
dc.contributor.authorSegura, R.
dc.contributor.authorAguirre, M.J.
dc.date.accessioned2025-01-30T18:01:38Z
dc.date.available2025-01-30T18:01:38Z
dc.date.issued2024-09-09
dc.date.updated2025-01-30T18:01:39Z
dc.description.abstractIn this study, a new and simple glassy carbon electrode modified with carbon nanohorns (SWCNH/GCE) was used for the determination of Cr(VI) in aqueous matrices via adsorptive cathodic stripping voltammetry (AdCSV). The modified electrode was characterized via field emission scanning electron microscopy and cyclic voltammetry, which revealed a homogeneous distribution of spherical agglomerates of SWCNH on the electrode surface. The modification increased the electrochemically active area from 0.10 cm2 ± 0.01 (GCE) to 0.16 cm2 ± 0.01 (SWCNH/GCE). The optimized analytical conditions were as follows: a supporting electrolyte (0.15 mol L−1 HCl), an accumulation potential of 0.8 V versus Ag/AgCl, and an accumulation time of 240 s. Validation of the analytical methodology was performed, obtaining a linear range between 20 and 100 µg L−1, a limit of detection of 3.5 µg L−1, and a limit of quantification of 11.6 µg L−1 with good accuracy and precision. The method was applied to the analysis of spiked tap water samples, and the results were compared using a flame atomic absorption spectrophotometer (FAAS) with no significant statistical differences.
dc.format.extent1 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec752427
dc.identifier.issn2079-4991
dc.identifier.urihttps://hdl.handle.net/2445/218270
dc.language.isoeng
dc.publisherMDPI
dc.relation.isformatofReproducció del document publicat a: https://doi.org/https://doi.org/10.3390/nano14171465
dc.relation.ispartofNanomaterials, 2024, vol. 14, num.17
dc.relation.urihttps://doi.org/https://doi.org/10.3390/nano14171465
dc.rightscc-by (c) Liendo, F. et al., 2024
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationCarbó
dc.subject.classificationElectroquímica
dc.subject.classificationVoltametria
dc.subject.otherCoal
dc.subject.otherElectrochemistry
dc.subject.otherVoltammetry
dc.titleElectrochemical sensor based on glassy carbon electrode modified with carbon nanohorns (SWCNH) for determination of Cr(VI) via adsorptive cathodic stripping voltammetry (AdCSV) in tap water
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
872818.pdf
Mida:
2.16 MB
Format:
Adobe Portable Document Format