Radial dose function of a 90Sr 90Y seed in water and A150: Comment on Calibration and characterization of beta-particle sources for intravascular brachytherapy

dc.contributor.authorAsenjo, J.cat
dc.contributor.authorFernández Varea, José Maríacat
dc.contributor.authorSánchez-Reyes, A.cat
dc.contributor.authorWang, C.-K.cat
dc.date.accessioned2012-05-03T11:19:54Z
dc.date.available2012-05-03T11:19:54Z
dc.date.issued2002
dc.date.updated2012-05-02T11:55:12Z
dc.description.abstractIntravascular brachytherapy with beta sources has become a useful technique to prevent restenosis after cardiovascular intervention. In particular, the Beta-Cath high-dose-rate system, manufactured by Novoste Corporation, is a commercially available 90Sr 90Y source for intravascular brachytherapy that is achieving widespread use. Its dosimetric characterization has attracted considerable attention in recent years. Unfortunately, the short ranges of the emitted beta particles and the associated large dose gradients make experimental measurements particularly difficult. This circumstance has motivated the appearance of a number of papers addressing the characterization of this source by means of Monte Carlo simulation techniques.eng
dc.format.extent2 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec504251
dc.identifier.issn0094-2405
dc.identifier.urihttps://hdl.handle.net/2445/24863
dc.language.isoeng
dc.publisherThe American Association of Physicists in Medicine
dc.relation.isformatofReproducció del document publicat a: http://dx.doi.org/10.1118/1.1510455
dc.relation.ispartofMedical Physics, 2002, vol. 29, p. 2737-2738
dc.relation.urihttp://dx.doi.org/10.1118/1.1510455
dc.rights(c) The American Association of Physicists in Medicine, 2002
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Física Quàntica i Astrofísica)
dc.subject.classificationMètode de Montecarlo
dc.subject.classificationAnisotropia
dc.subject.classificationFísica mèdica
dc.subject.classificationBraquiteràpia
dc.subject.otherMontecarlo method
dc.subject.otherAnisotropy
dc.subject.otherMedical physics
dc.subject.otherRadioisotope brachytherapy
dc.titleRadial dose function of a 90Sr 90Y seed in water and A150: Comment on Calibration and characterization of beta-particle sources for intravascular brachytherapy
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
504251.pdf
Mida:
34.19 KB
Format:
Adobe Portable Document Format