Contribution of the BioballTM head-neck adapter to the restoration of femoral offset in hip revision arthroplasty with retention of a well-fixed cup and stem

dc.contributor.authorMuñoz Mahamud, Ernesto
dc.contributor.authorChimeno, Clara
dc.contributor.authorFernández-Valencia, J. A. (Jenaro-Ángel)
dc.contributor.authorAlías, Alfonso
dc.contributor.authorSerra, Adrià
dc.contributor.authorPostnikov, Yury
dc.contributor.authorCombalía Aleu, Andrés
dc.date.accessioned2025-03-27T08:10:52Z
dc.date.available2025-03-27T08:10:52Z
dc.date.issued2023-05-15
dc.date.updated2025-03-27T08:10:52Z
dc.description.abstractPurpose: Failure to restore the femoral offset of the native hip is a potential cause of dysfunctional hip arthroplasty. The aim of this study was to report our experience of using a modular head-neck adapter in revision THA, specifically analyzing its usefulness as a tool to correct a slightly diminished femoral offset. Materials and methods: This was a retrospective single-center study including all hip revisions performed at our institution from January 2017 to March 2022 where the BioBallTM head-neck metal adapter was used. The preoperative and one year follow-up modified Merle d'Aubigné hip score was used to evaluate functional outcomes. Results: Of a total of 34 cases included for revision, the head-neck adapter system was used specifically in six patients (17.6%) to increase femoral offset, retaining both the acetabular and femoral components. In this subgroup of patients, mean offset decrease after primary THA was 6.6 mm (4.0-9.1), equivalent to a mean 16.3% femoral offset reduction. The median modified Merle d'Aubigné score went from 13.3 preoperatively to 16.2 at one year follow-up. Conclusion: The use of a head-neck adapter is a safe and reliable procedure that may allow the surgeon to easily correct a slightly diminished femoral offset in a dysfunctional THA without the need to revise well-fixed prosthetic components.
dc.format.extent7 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec738671
dc.identifier.issn0341-2695
dc.identifier.pmid37188902
dc.identifier.urihttps://hdl.handle.net/2445/220053
dc.language.isoeng
dc.publisherSpringer Verlag
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1007/s00264-023-05833-7
dc.relation.ispartofInternational Orthopaedics, 2023, vol. 47, p. 2245-2251
dc.relation.urihttps://doi.org/10.1007/s00264-023-05833-7
dc.rightscc by (c) Muñoz Mahamud, Ernesto et al., 2023
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceArticles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
dc.subject.classificationCirurgia ortopèdica
dc.subject.classificationTraumatologia
dc.subject.classificationCirurgia dels ossos
dc.subject.otherOrthopedic surgery
dc.subject.otherTraumatology
dc.subject.otherSurgery of bones
dc.titleContribution of the BioballTM head-neck adapter to the restoration of femoral offset in hip revision arthroplasty with retention of a well-fixed cup and stem
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
826407.pdf
Mida:
777.27 KB
Format:
Adobe Portable Document Format