Effectiveness of a new one-hour blood pressure monitoring method to diagnose hypertension: a diagnostic accuracy clinical trial protocol

dc.contributor.authorGonzález de Paz, Luis
dc.contributor.authorKostov, Belchin
dc.contributor.authorAlvira Balada, Maria del Carme
dc.contributor.authorColungo Francia, Cristina
dc.contributor.authorGarcía, Noemí
dc.contributor.authorRoura-Rovira, Silvia
dc.contributor.authorBlat, Esther
dc.contributor.authorSierra, Cristina
dc.contributor.authorSotoca Momblona, Josep Miquel
dc.contributor.authorBenavent Àreu, Jaume
dc.contributor.authorSánchez, Eva
dc.contributor.authorSisó Almirall, Antoni
dc.contributor.authorOMBP Group
dc.date.accessioned2020-04-29T11:21:32Z
dc.date.available2020-04-29T11:21:32Z
dc.date.issued2018-05-27
dc.date.updated2020-04-29T11:21:32Z
dc.description.abstractINTRODUCTION: 24-hour ambulatory blood pressure monitoring (ABPM) is the gold standard diagnostic method for hypertension, but has some shortcomings in clinical practice while clinical settings often lack sufficient devices to accommodate all patients with suspected hypertension. Home blood pressure monitoring (HBPM) and office blood pressure monitoring (OBPM) also have shortcomings, such as the white coat effect or a lack of accuracy. This study aims to study the validity of a new method of diagnosing hypertension consisting of monitoring blood pressure (BP) for 1 hour and comparing it with OBPM and HBPM and examining the sensitivity and specificity of this method compared with 24-hour ABPM. The patient experience will be examined in each method. METHODS AND ANALYSIS: A minimum sample of 214 patients requiring a diagnostic test for hypertension from three urban primary healthcare centres will be included. Participants will undergo 24-hour ABPM, 1-hour BP measurement (1-BPM), OBPM for three consecutive weeks and HBPM. Patients will follow a random sequence to first receive 24-hour ABPM or 1-hour ABPM. Daytime 24-hour ABPM records will be compared with the other monitoring methods using the correlation coefficient and Bland Altman plots. The kappa concordance index and the sensitivity and specificity of the methods will be calculated. The patient's experience will be studied, with selected indicators of efficiency and satisfaction calculated using parametric tests. ETHICS AND DISSEMINATION: The protocol has been authorised by the research ethics committee of the Hospital Clinic of Barcelona (Ref. HCB/2014/0615): protocol details and amendments will be recorded and reported to ClinicalTrials.com. The results will be disseminated in peer-reviewed literature, and to policy makers and healthcare partners. TRIAL REGISTRATION: NCT03147573; Pre-results.
dc.format.extent6 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec694985
dc.identifier.issn2044-6055
dc.identifier.pmid31133597
dc.identifier.urihttps://hdl.handle.net/2445/158017
dc.language.isoeng
dc.publisherBMJ Publishing Group
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1136/bmjopen-2019-029268
dc.relation.ispartofBMJ Open, 2018, vol. 9, num. 5, p. e029268
dc.relation.urihttps://doi.org/10.1136/bmjopen-2019-029268
dc.rightscc-by (c) González de Paz, Luis et al., 2018
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es
dc.sourceArticles publicats en revistes (Medicina)
dc.subject.classificationAssaigs clínics
dc.subject.classificationPressió sanguínia
dc.subject.otherClinical trials
dc.subject.otherBlood pressure
dc.titleEffectiveness of a new one-hour blood pressure monitoring method to diagnose hypertension: a diagnostic accuracy clinical trial protocol
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
694985.pdf
Mida:
1.45 MB
Format:
Adobe Portable Document Format