A proposal for a new lung ultrasound score in rheumatoid arthritis: the reliability of lung ultrasound for rheumatoid arthritis-associated interstitial lung disease diagnosis

dc.contributor.authorVicente Rabaneda, Esther F.
dc.contributor.authorMöller, Ingrid
dc.contributor.authorMata, Abdon
dc.contributor.authorMontes, Nuria
dc.contributor.authorRodríguez Vargas, Gabriel Santiago
dc.contributor.authorCoronel Tarancón, Luis
dc.contributor.authorBong, David A.
dc.contributor.authorCastañeda, Santos
dc.contributor.authorSantos Moreno, Pedro
dc.date.accessioned2025-07-16T09:30:44Z
dc.date.available2025-07-16T09:30:44Z
dc.date.issued2025-05-25
dc.date.updated2025-07-15T07:51:20Z
dc.description.abstractBackground/Objectives: The objective of this study is to investigate the intra- and inter-explorer reliability of different lung ultrasound (LUS) scores in patients with suspected rheumatoid arthritis with associated interstitial lung disease (RA-ILD). Methods: Fourteen consecutive patients with suspected RA-ILD based on the presence of respiratory symptoms, lung function tests (LFTs) or imaging alterations were recruited. The screening protocol consisted of an LFT, a chest X-ray, and HRCT. LUS examinations of different B-line and pleural line scores including 14 intercostal spaces were performed by three experienced sonographers, guaranteeing blinding. Intra- and inter-explorer reliability were calculated for all LUS scores and at the intercostal space level by weighted Cohen's kappa and Fleiss' kappa, respectively, relying on absolute differences using Stata/IC 14.2 software (R) (StataCorp, College Station, TX, USA). Results: Both global (& kgreen; = 0.73-0.82) and binary (& kgreen; = 0.80-0.90) scores of B lines showed substantial to excellent intra-explorer reliability, with slightly better results for the binary score. The inter-explorer reliability was equally excellent for the global score (& kgreen; = 0.93) and the binary score (& kgreen; = 0.90) of B lines. The intra-explorer reliability of the semiquantitative pleural score was excellent for all the sonographers (& kgreen; = 0.88-0.91), and the binary pleural score had slightly lower intra-explorer reliability (& kgreen; = 0.77-0.84). Regarding inter-explorer reliability, both semiquantitative and binary pleural scores were equally excellent (& kgreen; = 0.84). Good to excellent inter-explorer reliability was found in all the scanned areas. Conclusions: Substantial to excellent intra- and inter-explorer reliability of different feasible B-line and pleural LUS scores were found, adding evidence in favor of the potential implementation of LUS for RA-ILD diagnosis in clinical practice.
dc.format.extent20 p.
dc.format.mimetypeapplication/pdf
dc.identifier.issn2077-0383
dc.identifier.pmid40507462
dc.identifier.urihttps://hdl.handle.net/2445/222283
dc.language.isoeng
dc.publisherMDPI
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/jcm14113701
dc.relation.ispartofJournal of Clinical Medicine, 2025, vol. 14, num. 11, 3701
dc.relation.urihttps://doi.org/10.3390/jcm14113701
dc.rightscc-by (c) Vicente Rabaneda, Esther F. et al., 2025
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.sourceArticles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))
dc.subject.classificationArtritis reumatoide
dc.subject.classificationDiagnòstic per la imatge
dc.subject.otherRheumatoid arthritis
dc.subject.otherDiagnostic imaging
dc.titleA proposal for a new lung ultrasound score in rheumatoid arthritis: the reliability of lung ultrasound for rheumatoid arthritis-associated interstitial lung disease diagnosis
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
jcm-14-03701.pdf
Mida:
802.99 KB
Format:
Adobe Portable Document Format