Comparison of 2D versus M-mode echocardiography for assessing fetal myocardial wall thickness

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

OBJECTIVE: M-mode and 2D have been proposed for evaluating fetal myocardial thickness. However, studies comparing the performance of both modalities are lacking. We aimed to compare 2D versus M-mode reproducibility for assessing myocardial wall thicknesses. METHODS: A prospective study including 45 healthy fetuses from low-risk pregnancies evaluated between 18 and 41 weeks of gestation. Left and right ventricular free-wall and septal myocardial thicknesses were measured at end-diastole (ED) and end-systole (ES) in transverse 4-chamber view using 2D and M-mode. Intra- and interobserver reproducibility was evaluated by the concordance correlation coefficient (CCC). Both techniques were compared by t-test of the CCC. RESULTS: 2D and M-mode demonstrated excellent and similar intraobserver repeatability, with the best concordance in ES septal thickness (M-mode CCC 0.956 versus 2D-mode CCC 0.914). Interobserver reproducibility demonstrated also a high concordance, optimal in ES left ventricular free wall (M-mode 0.925 versus 2 D 0.855). Comparison of both techniques demonstrated a high concordance in all measurements, except for ED septal thickness with better reproducibility using M-mode (CCC 0.954 versus 0.847, p = .017). CONCLUSIONS: 2D and M-mode can be used in a reproducible manner for measuring fetal myocardial thickness, with a slightly better performance of M-mode for assessing ED septal wall thickness.

Citació

Citació

SEPÚLVEDA MARTÍNEZ, Álvaro, et al. Comparison of 2D versus M-mode echocardiography for assessing fetal myocardial wall thickness. Journal Of Maternal-Fetal & Neonatal Medicine. 2018. Vol. 32, num. 14, pags. 2319-2327. ISSN 1476-7058. [consulted: 7 of August of 2026]. Available at: https://hdl.handle.net/2445/145218

Exportar metadades

JSON - METS

Compartir registre