Comparison of 2D versus M-mode echocardiography for assessing fetal myocardial wall thickness

dc.contributor.authorSepúlveda Martínez, Álvaro
dc.contributor.authorGarcía-Otero, Laura
dc.contributor.authorSoveral, Iris
dc.contributor.authorGuirado, Laura
dc.contributor.authorValenzuela Alcaraz, Brenda I.
dc.contributor.authorTorres, Ximena
dc.contributor.authorRodríguez López, Mérida
dc.contributor.authorGratacós Solsona, Eduard
dc.contributor.authorGómez, Olga
dc.contributor.authorCrispi Brillas, Fàtima
dc.date.accessioned2019-11-21T11:05:26Z
dc.date.available2019-11-21T11:05:26Z
dc.date.issued2018-02-11
dc.date.updated2019-11-21T11:05:26Z
dc.description.abstractOBJECTIVE: M-mode and 2D have been proposed for evaluating fetal myocardial thickness. However, studies comparing the performance of both modalities are lacking. We aimed to compare 2D versus M-mode reproducibility for assessing myocardial wall thicknesses. METHODS: A prospective study including 45 healthy fetuses from low-risk pregnancies evaluated between 18 and 41 weeks of gestation. Left and right ventricular free-wall and septal myocardial thicknesses were measured at end-diastole (ED) and end-systole (ES) in transverse 4-chamber view using 2D and M-mode. Intra- and interobserver reproducibility was evaluated by the concordance correlation coefficient (CCC). Both techniques were compared by t-test of the CCC. RESULTS: 2D and M-mode demonstrated excellent and similar intraobserver repeatability, with the best concordance in ES septal thickness (M-mode CCC 0.956 versus 2D-mode CCC 0.914). Interobserver reproducibility demonstrated also a high concordance, optimal in ES left ventricular free wall (M-mode 0.925 versus 2 D 0.855). Comparison of both techniques demonstrated a high concordance in all measurements, except for ED septal thickness with better reproducibility using M-mode (CCC 0.954 versus 0.847, p = .017). CONCLUSIONS: 2D and M-mode can be used in a reproducible manner for measuring fetal myocardial thickness, with a slightly better performance of M-mode for assessing ED septal wall thickness.
dc.format.extent24 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec678938
dc.identifier.issn1476-7058
dc.identifier.urihttps://hdl.handle.net/2445/145218
dc.language.isoeng
dc.publisherInforma UK Ltd.
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1080/14767058.2018.1432041
dc.relation.ispartofJournal Of Maternal-Fetal & Neonatal Medicine, 2018, vol. 32, num. 14, p. 2319-2327
dc.relation.urihttps://doi.org/10.1080/14767058.2018.1432041
dc.rights(c) Informa UK Ltd., 2018
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
dc.subject.classificationEcocardiografia
dc.subject.classificationCor
dc.subject.classificationFetus
dc.subject.classificationEstudi de casos
dc.subject.otherEchocardiography
dc.subject.otherHeart
dc.subject.otherFetus
dc.subject.otherCase studies
dc.titleComparison of 2D versus M-mode echocardiography for assessing fetal myocardial wall thickness
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
678938.pdf
Mida:
717.62 KB
Format:
Adobe Portable Document Format