Comparison of 2D versus M-mode echocardiography for assessing fetal myocardial wall thickness
| dc.contributor.author | Sepúlveda Martínez, Álvaro | |
| dc.contributor.author | García-Otero, Laura | |
| dc.contributor.author | Soveral, Iris | |
| dc.contributor.author | Guirado, Laura | |
| dc.contributor.author | Valenzuela Alcaraz, Brenda I. | |
| dc.contributor.author | Torres, Ximena | |
| dc.contributor.author | Rodríguez López, Mérida | |
| dc.contributor.author | Gratacós Solsona, Eduard | |
| dc.contributor.author | Gómez, Olga | |
| dc.contributor.author | Crispi Brillas, Fàtima | |
| dc.date.accessioned | 2019-11-21T11:05:26Z | |
| dc.date.available | 2019-11-21T11:05:26Z | |
| dc.date.issued | 2018-02-11 | |
| dc.date.updated | 2019-11-21T11:05:26Z | |
| dc.description.abstract | OBJECTIVE: M-mode and 2D have been proposed for evaluating fetal myocardial thickness. However, studies comparing the performance of both modalities are lacking. We aimed to compare 2D versus M-mode reproducibility for assessing myocardial wall thicknesses. METHODS: A prospective study including 45 healthy fetuses from low-risk pregnancies evaluated between 18 and 41 weeks of gestation. Left and right ventricular free-wall and septal myocardial thicknesses were measured at end-diastole (ED) and end-systole (ES) in transverse 4-chamber view using 2D and M-mode. Intra- and interobserver reproducibility was evaluated by the concordance correlation coefficient (CCC). Both techniques were compared by t-test of the CCC. RESULTS: 2D and M-mode demonstrated excellent and similar intraobserver repeatability, with the best concordance in ES septal thickness (M-mode CCC 0.956 versus 2D-mode CCC 0.914). Interobserver reproducibility demonstrated also a high concordance, optimal in ES left ventricular free wall (M-mode 0.925 versus 2 D 0.855). Comparison of both techniques demonstrated a high concordance in all measurements, except for ED septal thickness with better reproducibility using M-mode (CCC 0.954 versus 0.847, p = .017). CONCLUSIONS: 2D and M-mode can be used in a reproducible manner for measuring fetal myocardial thickness, with a slightly better performance of M-mode for assessing ED septal wall thickness. | |
| dc.format.extent | 24 p. | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.idgrec | 678938 | |
| dc.identifier.issn | 1476-7058 | |
| dc.identifier.uri | https://hdl.handle.net/2445/145218 | |
| dc.language.iso | eng | |
| dc.publisher | Informa UK Ltd. | |
| dc.relation.isformatof | Versió postprint del document publicat a: https://doi.org/10.1080/14767058.2018.1432041 | |
| dc.relation.ispartof | Journal Of Maternal-Fetal & Neonatal Medicine, 2018, vol. 32, num. 14, p. 2319-2327 | |
| dc.relation.uri | https://doi.org/10.1080/14767058.2018.1432041 | |
| dc.rights | (c) Informa UK Ltd., 2018 | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | |
| dc.source | Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques) | |
| dc.subject.classification | Ecocardiografia | |
| dc.subject.classification | Cor | |
| dc.subject.classification | Fetus | |
| dc.subject.classification | Estudi de casos | |
| dc.subject.other | Echocardiography | |
| dc.subject.other | Heart | |
| dc.subject.other | Fetus | |
| dc.subject.other | Case studies | |
| dc.title | Comparison of 2D versus M-mode echocardiography for assessing fetal myocardial wall thickness | |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:eu-repo/semantics/acceptedVersion |
Fitxers
Paquet original
1 - 1 de 1