Magnesium hydrogen breath test using end-expiratory sampling to assess achlorhydria in pernicious anaemia patients

dc.contributor.authorHumbert Yagüe, Perecat
dc.contributor.authorLópez de Soria, P.cat
dc.contributor.authorFernández Bañares, Fernandocat
dc.contributor.authorJuncà i Piera, Jordicat
dc.contributor.authorBoix, J.cat
dc.contributor.authorPlanas Vilà, Ramoncat
dc.contributor.authorQuer Boniquet, Joan Carlescat
dc.contributor.authorDomenech, E.cat
dc.contributor.authorGassull, Miquel Àngelcat
dc.date.accessioned2011-07-07T12:30:38Z
dc.date.available2011-07-07T12:30:38Z
dc.date.issued1994
dc.description.abstractA modified magnesium hydrogen breath test, using end expiratory breath sampling, is described to investigate achlorhydria. The efficacy of this test in the diagnostic investigation of pernicious anaemia was compared with that of serum pepsinogen I. Twenty one patients with pernicious anaemia--that is, patients with achlorhydria--and 22 with healed duodenal ulcer and normal chlorhydria were studied. Magnesium hydrogen breath test, serum pepsinogen I, serum gastrin, and standard gastric acid secretory tests were performed in all subjects. The mean (SEM) hydrogen peak value was lower in patients with pernicious anaemia than in the duodenal ulcer group (21.7 (1.9) v 71.3 (5.2) ppm; p = 0.00005). The hydrogen peak value had a 95.2% sensitivity and a 100% specificity to detect pentagastrin resistant achlorhydria. Mean serum pepsinogen I concentrations were also significantly lower in patients with pernicious anaemia than in the duodenal ulcer group (10.7 (2.7) v 123.6 (11.8) micrograms/l p = 0.00005). Sensitivity and specificity to detect pernicious anaemia were both 100% for pepsinogen I. It is concluded that this modified magnesium hydrogen breath test is a simple, noninvasive, cost effective, and accurate method to assess achlorhydria and may be useful in the diagnostic investigation of patients with suspected pernicious anaemia.eng
dc.format.extent4 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec160909
dc.identifier.issn0017-5749
dc.identifier.pmid7959224
dc.identifier.urihttps://hdl.handle.net/2445/18662
dc.language.isoengeng
dc.publisherBMJ Groupeng
dc.relation.isformatofReproducció digital del document publicat a: http://dx.doi.org/10.1136/gut.35.9.1205cat
dc.relation.ispartofGut, 1994, vol. 35, núm. 9, p. 1205-1208
dc.relation.urihttp://dx.doi.org/10.1136/gut.35.9.1205
dc.rights(c) BMJ Publishing Group Ltd and British Society of Gastroenterology, 1994
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Medicina)
dc.subject.classificationAnèmia perniciosacat
dc.subject.otherPernicious anemiaeng
dc.titleMagnesium hydrogen breath test using end-expiratory sampling to assess achlorhydria in pernicious anaemia patientseng
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
160909.pdf
Mida:
746.05 KB
Format:
Adobe Portable Document Format