Accuracy of standard bipolar amplitude voltage thresholds to identify late potential channels in ventricular tachycardia ablation

dc.contributor.authorRoca Luque, Ivo
dc.contributor.authorZaraket, Fatima
dc.contributor.authorGarre Anguera de Sojo, Paz
dc.contributor.authorSánchez Somonte, Paula
dc.contributor.authorQuinto, Levio
dc.contributor.authorBorras, Roger
dc.contributor.authorGuasch i Casany, Eduard
dc.contributor.authorArbelo, Elena
dc.contributor.authorTolosana, José M. (José María)
dc.contributor.authorBrugada Terradellas, Josep, 1958-
dc.contributor.authorMont Girbau, Lluís
dc.date.accessioned2024-07-03T13:49:21Z
dc.date.available2024-07-03T13:49:21Z
dc.date.issued2022-02-23
dc.date.updated2024-07-03T13:49:26Z
dc.description.abstractBackground: Ventricular tachycardia (VT) is caused by the presence of a slow conduction channel (CC) of border zone (BZ) tissue inside the scar-core tissue. Electroanatomic mapping can depict this tissue by voltage mapping. Areas of slow conduction can be detected as late potentials (LPs) and their abolition is the most accepted ablation endpoint. In the current guidelines, bipolar voltage thresholds for BZ and core scar are 1.5 and 0.5 mV respectively. The performance of these values is controversial. The aim of the study is to analyze the diagnostic yield of current amplitude thresholds in voltage map to define VT substrate in terms of CCs of LPs. Predictors of usefulness of current thresholds will be analyzed. Methods: All patients with structural heart disease who underwent VT ablation in Hospital Clinic in 2016-2017 were included. Maps with delineation of CCs based on LPs were created with contact force sensor catheter. Thresholds were adjusted for every patient based on CCs. Diagnostic yield and predictors of performance of conventional thresholds were analyzed. Results: During study period, 57 consecutive patients were included (age: 60.4 ± 8.5; 50.2% ischemic cardiomyopathy, LVEF 39.8 ± 13.5%). Cutoff voltages that better identified the scar and BZ according to the LP channels were 0.32 (0.02-2 mV) and 1.84 (0.3-6 mV) respectively. Current voltage thresholds identified correctly core and BZ in 87.7% and 42.1% of the patients respectively. Accuracy was worse in non-ischemic cardiomyopathy (NICM) especially for BZ (28.6% vs 55.2%, p = 0.042). Conclusions: Accuracy of standard voltage thresholds for scar and BZ is poor in terms of LPs detection. Diagnostic yield is worse in NICM patients specially for border zone.
dc.format.extent11 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec722192
dc.identifier.issn1383-875X
dc.identifier.pmid35195814
dc.identifier.urihttps://hdl.handle.net/2445/214271
dc.language.isoeng
dc.publisherSpringer Verlag
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1007/s10840-022-01148-6
dc.relation.ispartofJournal of Interventional Cardiac Electrophysiology, 2023, vol. 66, num.1, p. 15-25
dc.relation.urihttps://doi.org/10.1007/s10840-022-01148-6
dc.rightscc by (c) Roca Luque, Ivo et al., 2023
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0*
dc.sourceArticles publicats en revistes (Medicina)
dc.subject.classificationTaquicàrdia
dc.subject.classificationVentricles cardíacs
dc.subject.classificationCicatrius
dc.subject.classificationMalalties del cor
dc.subject.otherTachycardia
dc.subject.otherVentricle of heart
dc.subject.otherScars
dc.subject.otherHeart diseases
dc.titleAccuracy of standard bipolar amplitude voltage thresholds to identify late potential channels in ventricular tachycardia ablation
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
249295.pdf
Mida:
1.27 MB
Format:
Adobe Portable Document Format