High inappropriate red blood cell transfusion rate despite low overall use: a real-world multicenter study in 43 Spanish hospitals

dc.contributor.authorTamayo Velasco, Álvaro
dc.contributor.authorLlau Pitarch, Juan Vicente
dc.contributor.authorColomina Soler, M. J. (María José)
dc.contributor.authorDe la Varga Martínez, Olga
dc.contributor.authorNavarro Pérez, Rosalía
dc.contributor.authorLópez Herrero, Rocío
dc.contributor.authorAlmoguera Fernández, Jorge
dc.contributor.authorAlonso Fernández, Marta
dc.contributor.authorArtiaga-Candia, María
dc.contributor.authorBecerra-Bolaños, Angel
dc.contributor.authorBugueño, Natalia
dc.contributor.authorCasasempere Sanus, Alma
dc.contributor.authorContreras López, Laura
dc.contributor.authorHeredia Rodríguez, María
dc.contributor.authorde la Fuente Graciani, Ignacio
dc.contributor.authorDe la Rosa-Estadella, Marta
dc.contributor.authorDe la Torre Riveiro, Iria
dc.contributor.authorDel Val Peciña, Elena
dc.contributor.authorDelgado Martí, Carla
dc.contributor.authorEdo Cebollada, Laura
dc.contributor.authorFernández Fernández, Ricardo
dc.contributor.authorFernández Rodríguez, Jorge
dc.contributor.authorFerrer Gómez, Carolina
dc.contributor.authorGiné Servén, Marta
dc.contributor.authorGonzález Pereira, Almudena
dc.contributor.authorGuereca Gala, Ane
dc.contributor.authorHerrera Soto, Aurora
dc.contributor.authorInfantes Morales, Marta E.
dc.contributor.authorMarcos Vidal, José Miguel
dc.contributor.authorIllodo Miramontes, Gustavo
dc.contributor.authorMartínez López, Adrián
dc.contributor.authorMartínez Ruiz, Alberto
dc.contributor.authorMartínez Rafael, Beatriz
dc.contributor.authorMatute González, Adrián
dc.contributor.authorPariente Juste, Laura
dc.contributor.authorPérez González, Sonia
dc.contributor.authorGómez Pesquera, Estefania
dc.contributor.authorRenedo Fernández, Ainhoa
dc.contributor.authorRodríguez Álvarez, Ángel A.
dc.contributor.authorSánchez Rodríguez, Iván
dc.contributor.authordel Aranzazú Rodríguez-Conesa, María
dc.contributor.authorSánchez González, Cristina
dc.contributor.authorTobar Gonzalo, Cristina
dc.contributor.authorVarela Rodríguez, Lorena
dc.contributor.authorVeloso de Sousa, Rita
dc.contributor.authorMuñoz Moreno, María Fe
dc.contributor.authorGarcía-Sánchez, José
dc.contributor.authorRocha García, Felipe
dc.contributor.authorGonzález Montes, Pablo
dc.contributor.authorCid Boo, Patricia
dc.contributor.authorEscudero Gómez, Gabriel
dc.contributor.authorRomero García, Nekane
dc.contributor.authorCots, Ana
dc.contributor.authorPeñarrubia Ponce, Maria Jesus
dc.contributor.authorHornero, Roberto
dc.contributor.authorSantamaría-Vázquez, Eduardo
dc.contributor.authorPoves Álvarez, Rodrigo
dc.contributor.authorTamayo, Eduardo
dc.contributor.authorVarela Duran, Marina
dc.contributor.authorBadenes, Rafael
dc.date.accessioned2026-10-06T16:45:29Z
dc.date.available2026-10-06T16:45:29Z
dc.date.issued2026-05-14
dc.date.updated2026-10-06T16:45:31Z
dc.description.abstractBackground: Since their implementation in Spain, adherence of hospitals to Patient Blood Management (PBM) programs has been variable, potentially influencing transfusion practices. This study aimed to evaluate, in a real-world surgical setting, the frequency and appropriateness of red blood cell (RBC) transfusion. Methods: A prospective multicenter study in 43 Spanish hospitals including surgical patients. Transfusion appropriateness was evaluated using evidence-based criteria based on hemoglobin thresholds and clinical conditions such as cardiovascular disease, acute hemorrhage, or high comorbidity burden. Statistical analyses identified factors associated with transfusion practices. Results: The overall perioperative RBC transfusion rate was 9.7%, with the highest rates in cardiac (52.9%), vascular (17.9%), and orthopedic (12.3%) surgeries. RBC transfusion was associated with older patients with comorbidities, lower preoperative hemoglobin, higher ASA score and worse surgical meters and postoperative outcomes. Transfused patients showed significantly lower 60-day survival. Critically, 43% of transfusions were inappropriate, while transfusion omission (1.9%) may represent a clinical concern that warrants further investigation. Inappropriate transfusion was more frequent in older comorbidity patients according to Charlson Comorbidity Index in urgent surgery. In multivariable analysis, age was a factor associated with inappropriate transfusion, by cons, surgical blood loss was the main protective factor against inappropriate transfusion. Conclusion: As far as we know, this is the first Spanish multicenter study evaluating transfusion appropriateness in surgical scenario. Despite a lower overall transfusion rate than international figures, nearly half of transfusions were inappropriate and transfusion omission, also represents a real clinical concern. Implementation of decision-support tools and strengthened PBM protocols are needed to address factors associated with inappropriate transfusion, such as age, and to optimize patient safety and resource use.
dc.format.extent11 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec771183
dc.identifier.issn2296-858X
dc.identifier.pmid42221112
dc.identifier.urihttps://hdl.handle.net/2445/231916
dc.language.isoeng
dc.publisherFrontiers Media
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3389/fmed.2026.1803092
dc.relation.ispartofFrontiers in Medicine, 2026, vol. 13
dc.relation.urihttps://doi.org/10.3389/fmed.2026.1803092
dc.rightscc-by (c) Tamayo-Velasco, Á. et al., 2026
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.classificationTransfusió de sang
dc.subject.classificationHemoglobina
dc.subject.otherBlood transfusion
dc.subject.otherHemoglobin
dc.titleHigh inappropriate red blood cell transfusion rate despite low overall use: a real-world multicenter study in 43 Spanish hospitals
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
940969.pdf
Mida:
1.14 MB
Format:
Adobe Portable Document Format