Influence of particle size on extrapleural talc dissemination after talc slurry pleurodesis

dc.contributor.authorFerrer Amorós, Jaume R.
dc.contributor.authorMontes Castillo, Juan Francisco
dc.contributor.authorVillarino, María A.
dc.contributor.authorLight, Richard W.
dc.contributor.authorGarcia Valero, Josep
dc.date.accessioned2022-03-02T15:33:48Z
dc.date.available2022-03-02T15:33:48Z
dc.date.issued2002-09-01
dc.date.updated2022-03-02T15:33:48Z
dc.description.abstractCases of acute respiratory failure reported after talc pleurodesis have raised concerns about its safety. It has been speculated that this pulmonary inflammatory syndrome is secondary to the extrapleural dissemination of the talc particles. Study objectives: To test the hypothesis that particle size influences extrapleural talc deposition and pleural inflammation after talc slurry pleurodesis. Design: Thirty rabbits underwent pleurodesis as follows: 10 rabbits received 200 mg/kg of the talc used for human pleurodesis, normal talc (NT); 10 rabbits received 200 mg/kg of talc with particles of larger size, large talc (LT); and 10 rabbits received saline solution. Samples from the ipsilateral lung, chest wall, diaphragm, mediastinal pleura, heart, liver, spleen, and right kidney were obtained at 24 h and 7 days and processed for optic and electron microscopy and energydispersive x-ray analysis. Results: Visceral pleural thickening was greater with NT than with LT, but no differences were observed in the macroscopic score of adhesions. There was more talc in the lungs of the rabbits that received NT than in those that received LT. Talc particles were detected in mediastinum (100%) and pericardium (20%), irrespective of the talc used. Three animals, all receiving NT, had talc particles in the liver. Conclusions: Our study shows that while both talcs were equally effective in achieving pleurodesis, the intrapleural injection of NT elicits greater pulmonary and systemic talc particle deposition than LT. Moreover, pleural inflammation was greater with NT than with LT.
dc.format.extent10 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec514384
dc.identifier.issn0012-3692
dc.identifier.urihttps://hdl.handle.net/2445/183690
dc.language.isoeng
dc.publisherAmerican College of Chest Physicians
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1378/chest.122.3.1018
dc.relation.ispartofChest, 2002, vol. 122, num. 3, p. 1018-1027
dc.relation.urihttps://doi.org/10.1378/chest.122.3.1018
dc.rights(c) American College of Chest Physicians, 2002
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Biologia Cel·lular, Fisiologia i Immunologia)
dc.subject.classificationPleuresia
dc.subject.classificationTalc
dc.subject.classificationGranulometria
dc.subject.otherPleuresy
dc.subject.otherTalc
dc.subject.otherParticle size determination
dc.titleInfluence of particle size on extrapleural talc dissemination after talc slurry pleurodesis
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
514384.pdf
Mida:
2.43 MB
Format:
Adobe Portable Document Format