Validity and Reliability of Dermoscopic Criteria Used to Differentiate Nevi From Melanoma: A Web-Based International Dermoscopy Society Study.

dc.contributor.authorCarrera Álvarez, Cristina
dc.contributor.authorMarchetti, Michael A.
dc.contributor.authorDusza, Stephen W.
dc.contributor.authorArgenziano, Giuseppe
dc.contributor.authorBraun, Ralph P.
dc.contributor.authorHalpern, Allan C.
dc.contributor.authorJaimes, Natalia
dc.contributor.authorKittler, Harald J.
dc.contributor.authorMalvehy, J. (Josep)
dc.contributor.authorMenzies, Scott W.
dc.contributor.authorPellacani, Giovanni
dc.contributor.authorPuig i Sardà, Susana
dc.contributor.authorRabinovitz, Harold S.
dc.contributor.authorScope, Alon
dc.contributor.authorSoyer, H.Peter
dc.contributor.authorStolz, Wilhem
dc.contributor.authorHofmann-Wellenhof, Rainer
dc.contributor.authorZalaudek, Iris
dc.contributor.authorMarghoob, Ashfaq A.
dc.date.accessioned2017-05-29T14:03:19Z
dc.date.available2017-07-31T22:01:33Z
dc.date.issued2016-07-01
dc.date.updated2017-05-29T14:03:19Z
dc.description.abstractIMPORTANCE: The comparative diagnostic performance of dermoscopic algorithms and their individual criteria are not well studied. OBJECTIVES: To analyze the discriminatory power and reliability of dermoscopic criteria used in melanoma detection and compare the diagnostic accuracy of existing algorithms. DESIGN, SETTING, AND PARTICIPANTS: This was a retrospective, observational study of 477 lesions (119 melanomas [24.9%] and 358 nevi [75.1%]), which were divided into 12 image sets that consisted of 39 or 40 images per set. A link on the International Dermoscopy Society website from January 1, 2011, through December 31, 2011, directed participants to the study website. Data analysis was performed from June 1, 2013, through May 31, 2015. Participants included physicians, residents, and medical students, and there were no specialty-type or experience-level restrictions. Participants were randomly assigned to evaluate 1 of the 12 image sets. MAIN OUTCOMES AND MEASURES: Associations with melanoma and intraclass correlation coefficients (ICCs) were evaluated for the presence of dermoscopic criteria. Diagnostic accuracy measures were estimated for the following algorithms: the ABCD rule, the Menzies method, the 7-point checklist, the 3-point checklist, chaos and clues, and CASH (color, architecture, symmetry, and homogeneity). RESULTS: A total of 240 participants registered, and 103 (42.9%) evaluated all images. The 110 participants (45.8%) who evaluated fewer than 20 lesions were excluded, resulting in data from 130 participants (54.2%), 121 (93.1%) of whom were regular dermoscopy users. Criteria associated with melanoma included marked architectural disorder (odds ratio [OR], 6.6; 95% CI, 5.6-7.8), pattern asymmetry (OR, 4.9; 95% CI, 4.1-5.8), nonorganized pattern (OR, 3.3; 95% CI, 2.9-3.7), border score of 6 (OR, 3.3; 95% CI, 2.5-4.3), and contour asymmetry (OR, 3.2; 95% CI, 2.7-3.7) (P < .001 for all). Most dermoscopic criteria had poor to fair interobserver agreement. Criteria that reached moderate levels of agreement included comma vessels (ICC, 0.44; 95% CI, 0.40-0.49), absence of vessels (ICC, 0.46; 95% CI, 0.42-0.51), dark brown color (ICC, 0.40; 95% CI, 0.35-0.44), and architectural disorder (ICC, 0.43; 95% CI, 0.39-0.48). The Menzies method had the highest sensitivity for melanoma diagnosis (95.1%) but the lowest specificity (24.8%) compared with any other method (P < .001). The ABCD rule had the highest specificity (59.4%). All methods had similar areas under the receiver operating characteristic curves. CONCLUSIONS AND RELEVANCE: Important dermoscopic criteria for melanoma recognition were revalidated by participants with varied experience. Six algorithms tested had similar but modest levels of diagnostic accuracy, and the interobserver agreement of most individual criteria was poor.
dc.format.extent9 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec668004
dc.identifier.issn2168-6068
dc.identifier.pmid27074267
dc.identifier.urihttps://hdl.handle.net/2445/111683
dc.language.isoeng
dc.publisherAmerican Medical Association
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1001/jamadermatol.2016.0624
dc.relation.ispartofJAMA Dermatology, 2016, vol. 152, num. 7, p. 798-806
dc.relation.urihttps://doi.org/10.1001/jamadermatol.2016.0624
dc.rights(c) American Medical Association, 2016
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Medicina)
dc.subject.classificationMelanoma
dc.subject.classificationDiagnòstic
dc.subject.classificationDermatologia
dc.subject.classificationCàncer
dc.subject.otherMelanoma
dc.subject.otherDiagnosis
dc.subject.otherDermatology
dc.subject.otherCancer
dc.titleValidity and Reliability of Dermoscopic Criteria Used to Differentiate Nevi From Melanoma: A Web-Based International Dermoscopy Society Study.
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
668004.pdf
Mida:
200.56 KB
Format:
Adobe Portable Document Format