Ion mobility–mass spectrometry of palytoxin-like compounds produced by Ostreopsis cf. ovata

dc.contributor.authorMedina Pérez, Noemí-Inmaculada
dc.contributor.authorPeralta Moreno, María Nuria
dc.contributor.authorRubio Martínez, Jaime
dc.contributor.authorBechtella, Leïla
dc.contributor.authorPolewski, Lukasz
dc.contributor.authorSzekeres, Gergo Peter
dc.contributor.authorBerdalet, Elisa
dc.contributor.authorMoyano Morcillo, Encarnación
dc.contributor.authorPagel, Kevin
dc.date.accessioned2026-01-21T18:10:45Z
dc.date.available2026-01-21T18:10:45Z
dc.date.issued2025-10-16
dc.date.updated2026-01-21T18:10:45Z
dc.description.abstractPalytoxin (PLTX) and its analogues from Ostreopsis cf. ovata are significant health concerns. They show potent vasoconstrictive properties, often causing seafood poisoning. PLTX analogues have chiral centers, resulting in many isomers, making their separation by liquid chromatography and identification/characterization by mass spectrometry challenging. This study explores for the first time the ion mobility spectrometry (IMS) behavior of these compounds to address these analytical challenges. Drift tube ion mobility spectrometry (DTIMS) and traveling wave ion mobility spectrometry (TWIMS) were used and compared. Additionally, trapped ion mobility spectrometry (TIMS) and molecular dynamics simulation were employed to explain unexpected results. TIMS provided higher resolution, distinguishing isomeric ions generated in the electrospray source by losing water molecules from different toxin sites. Computational studies offered theoretical insights into the ion mobility of triply charged calcium and sodium adduct ions, suggesting a folded conformation. DTCCSN2 (collisional cross section using DTIMS and nitrogen as buffer gas) values were obtained for PLTX (standard), ovatoxin-a, and ovatoxin-b from microalgae samples in Sant Andreu de Llavaneres (Barcelona, Spain). These values were comparable (ΔCCSs < 2%) to those measured with TWIMS calibrated using PLTX (standard). The study provides 102 CCS values from DTIMS and TWIMS data for adducts and fragment ions of PLTX analogues, which can be used as reference values in databases for toxin screening in complex samples.
dc.format.extent13 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec763942
dc.identifier.issn1618-2642
dc.identifier.urihttps://hdl.handle.net/2445/225916
dc.language.isoeng
dc.publisherSpringer Verlag
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1007/s00216-025-06158-7
dc.relation.ispartofAnalytical and Bioanalytical Chemistry, 2025, vol. 417, num.29, p. 6665-6677
dc.relation.urihttps://doi.org/10.1007/s00216-025-06158-7
dc.rightscc-by (c) Medina Pérez, N.I., et al., 2025
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.classificationCromatografia de gasos
dc.subject.classificationEspectrometria de masses
dc.subject.classificationQuímica analítica
dc.subject.otherGas chromatography
dc.subject.otherMass spectrometry
dc.subject.otherAnalytical chemistry
dc.titleIon mobility–mass spectrometry of palytoxin-like compounds produced by Ostreopsis cf. ovata
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
911928.pdf
Mida:
4.2 MB
Format:
Adobe Portable Document Format