High rate of uncovered struts in latest generation drug-eluting stents with durable, biodegradable polymer or lack of it 1 month after implantation

dc.contributor.authorCalvo Fernández, Alicia
dc.contributor.authorGómez Lara, Josep
dc.contributor.authorElosua, Roberto
dc.contributor.authorDurán, Xavier
dc.contributor.authorCubero Gallego, Héctor
dc.contributor.authorTizón Marcos, Helena
dc.contributor.authorSalvatella, Neus
dc.contributor.authorNegrete, Alejandro
dc.contributor.authorMillán, Raúl
dc.contributor.authorIvern, Consol
dc.contributor.authorDíez Gil, José Luís
dc.contributor.authorSánchez Carpintero, Andrea
dc.contributor.authorFarré, Núria
dc.contributor.authorTorre Hernández, José María de la
dc.contributor.authorVaquerizo, Beatriz
dc.date.accessioned2023-05-23T11:10:03Z
dc.date.available2023-05-23T11:10:03Z
dc.date.issued2023-02-07
dc.date.updated2023-04-17T12:50:53Z
dc.description.abstractIntroduction and objectives: Delayed vascular healing may induce late stent thrombosis. Optical coherence tomography (OCT) is useful to evaluate endothelial coverage. The objective of this study was to compare stent coverage and apposition in non-complex coronary artery lesions treated with durable polymer-coated everolimus-eluting stents (durable-polymer EES) vs biodegradable polymer-coated everolimus-eluting stents ( biodegradable-polymer EES) vs polymer-free biolimus-eluting stents (BES) 1 and 6 months after stent implantation. Methods: Prospective, multicenter, non-randomized study that compared the 3 types of DES. Follow-up angiography and OCT were performed 1 and 6 months later. The primary endpoint was the rate of uncovered struts as assessed by the OCT at 1 month. Results: A total of 104 patients with de novo non-complex coronary artery lesions were enrolled. A total of 44 patients were treated with polymer-free BES, 35 with biodegradable-polymer EES, and 25 with durable-polymer EES. A high rate of uncovered struts was found at 1 month with no significant differences reported among the stents (80.2%, polymer-free BES; 88.1%, biodegradable-polymer EES; 82.5%, durable-polymer EES; P =.209). Coverage improved after 6 months in the 3 groups without significant differences being reported (97%, 95%, and 93.7%, respectively; P =.172). Conclusions: In patients with de novo non-complex coronary artery lesions treated with durable vs biodegradable vs polymer-free DES, strut coverage and apposition were suboptimal at 1 month with significant improvement at 6 months.
dc.format.extent9 p.
dc.format.mimetypeapplication/pdf
dc.identifier.issn2604-7322
dc.identifier.urihttps://hdl.handle.net/2445/198333
dc.language.isoeng
dc.publisherPermanyer Publications, SLU
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.24875/RECICE.M22000343
dc.relation.ispartofREC: interventional cardiology (English Edition), 2023, vol. 5, num. 1, p. 20-28
dc.relation.urihttps://doi.org/10.24875/RECICE.M22000343
dc.rightscc by-nc-nd (c) Sociedad Española de Cardiología, 2022
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.sourceArticles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))
dc.subject.classificationPròtesis de Stent
dc.subject.classificationTrombosi
dc.subject.classificationAngiografia
dc.subject.classificationTomografia de coherència òptica
dc.subject.otherStents (Surgery)
dc.subject.otherThrombosis
dc.subject.otherAngiography
dc.subject.otherOptical coherence tomography
dc.titleHigh rate of uncovered struts in latest generation drug-eluting stents with durable, biodegradable polymer or lack of it 1 month after implantation
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
05_recic_22_043_ao_calvo_uk.pdf
Mida:
484.46 KB
Format:
Adobe Portable Document Format