Impact of operatoŕs experience on peri-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry
| dc.contributor.author | Cruz González, Ignacio | |
| dc.contributor.author | Torres Saura, Francisco | |
| dc.contributor.author | Trejo Velasco, Blanca | |
| dc.contributor.author | Fernández Díaz, José Antonio | |
| dc.contributor.author | Fajardo Molina, Ricardo | |
| dc.contributor.author | Valle Fernández, Raquel del | |
| dc.contributor.author | Moreno Terribas, Gerardo | |
| dc.contributor.author | Martí Sánchez, David | |
| dc.contributor.author | López Mínguez, José Ramón | |
| dc.contributor.author | Gómez Blázquez, Iván | |
| dc.contributor.author | Sanmartín Pena, Juan Carlos | |
| dc.contributor.author | Botas, Javier | |
| dc.contributor.author | Martín Lorenzo, Pedro | |
| dc.contributor.author | Palazuelos, Jorge | |
| dc.contributor.author | Albarrán Rincon, Ramón | |
| dc.contributor.author | Mohandes, Mohsen | |
| dc.contributor.author | Rodríguez Entem, Felipe José | |
| dc.contributor.author | Martí, Gerard | |
| dc.contributor.author | Valero, Ernesto | |
| dc.contributor.author | Gutiérrez, Hipólito | |
| dc.contributor.author | Amat Santos, Ignacio J. | |
| dc.contributor.author | Nombela Franco, Luis | |
| dc.contributor.author | Salinas, Pablo | |
| dc.contributor.author | Teruel, Luis | |
| dc.contributor.author | Gómez Hospital, Joan Antoni | |
| dc.contributor.author | Arzamendi, Dabit | |
| dc.contributor.author | Torres Sanabria, Mario | |
| dc.contributor.author | Calle Pérez, Germán | |
| dc.contributor.author | Cañadas Pruaño, Dolores | |
| dc.contributor.author | Pérez de Prado, Armando | |
| dc.contributor.author | Benito González, Tomás | |
| dc.contributor.author | Arroyo Úcar, Eduardo | |
| dc.contributor.author | Estévez Loureiro, Rodrigo | |
| dc.contributor.author | Caneiro Queija, Berenice | |
| dc.contributor.author | Ibañez Criado, José L. | |
| dc.contributor.author | Ruiz Nodar, Juan M. | |
| dc.date.accessioned | 2022-02-07T17:24:01Z | |
| dc.date.available | 2022-02-07T17:24:01Z | |
| dc.date.issued | 2021-12-29 | |
| dc.date.updated | 2022-02-07T17:24:01Z | |
| dc.description.abstract | Background: The Watchman FLX is a device upgrade of the Watchman 2.5 that incorporates several design enhancements intended to simplify left atrial appendage occlusion (LAAO) and improve procedural outcomes. This study compares peri-procedural results of LAAO with Watchman FLX (Boston Scientific, Marlborough, Massachusetts) in centers with varying degrees of experience with the Watchman 2.5 and Watchman FLX. Methods: Prospective, multicenter, 'real-world' registry including consecutive patients undergoing LAAO with the Watchman FLX at 26 Spanish sites (FLX-SPA registry). Implanting centers were classified according to the center's prior experience with the Watchman 2.5. A further division of centers according to whether or not they had performed ≤ 10 or > 10Watchman FLX implants was prespecified at the beginning of the study. Procedural outcomes of institutions stratified according to their experience with the Watchman 2.5 and FLX devices were compared. Results: 359 patients [mean age 75.5 (SD8.1), CHA2DS2-VASc 4.4 (SD1.4), HAS-BLED 3.8(SD0.9)] were included. Global success rate was 98.6%, successful LAAO with the first selected device size was achieved in 95.5% patients and the device was implanted at first attempt in 78.6% cases. There were only 9(2.5%) major peri-procedural complications. No differences in efficacy or safety results according to the centeŕs previous experience with Watchman 2.5 and procedural volume with Watchman FLX existed. Conclusions: The Watchman FLX attains high procedural success rates with complete LAA sealing in unselected, real-world patients, along with a low incidence of peri-procedural complications, regardless of operatoŕs experience with its previous device iteration or the number of Watchman FLX devices implanted. | |
| dc.format.extent | 8 p. | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.idgrec | 717891 | |
| dc.identifier.issn | 2352-9067 | |
| dc.identifier.uri | https://hdl.handle.net/2445/182998 | |
| dc.language.iso | eng | |
| dc.publisher | Elsevier B.V. | |
| dc.relation.isformatof | Reproducció del document publicat a: https://doi.org/10.1016/j.ijcha.2021.100941 | |
| dc.relation.ispartof | IJC Heart & Vasculature, 2021, vol. 38 | |
| dc.relation.uri | https://doi.org/10.1016/j.ijcha.2021.100941 | |
| dc.rights | cc-by-nc-nd (c) Cruz González, Ignacio et al., 2021 | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
| dc.source | Articles publicats en revistes (Ciències Clíniques) | |
| dc.subject.classification | Fibril·lació auricular | |
| dc.subject.classification | Implants artificials | |
| dc.subject.other | Atrial fibrillation | |
| dc.subject.other | Artificial implants | |
| dc.title | Impact of operatoŕs experience on peri-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry | |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:eu-repo/semantics/publishedVersion |
Fitxers
Paquet original
1 - 1 de 1