Impact of operatoŕs experience on peri-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry

dc.contributor.authorCruz González, Ignacio
dc.contributor.authorTorres Saura, Francisco
dc.contributor.authorTrejo Velasco, Blanca
dc.contributor.authorFernández Díaz, José Antonio
dc.contributor.authorFajardo Molina, Ricardo
dc.contributor.authorValle Fernández, Raquel del
dc.contributor.authorMoreno Terribas, Gerardo
dc.contributor.authorMartí Sánchez, David
dc.contributor.authorLópez Mínguez, José Ramón
dc.contributor.authorGómez Blázquez, Iván
dc.contributor.authorSanmartín Pena, Juan Carlos
dc.contributor.authorBotas, Javier
dc.contributor.authorMartín Lorenzo, Pedro
dc.contributor.authorPalazuelos, Jorge
dc.contributor.authorAlbarrán Rincon, Ramón
dc.contributor.authorMohandes, Mohsen
dc.contributor.authorRodríguez Entem, Felipe José
dc.contributor.authorMartí, Gerard
dc.contributor.authorValero, Ernesto
dc.contributor.authorGutiérrez, Hipólito
dc.contributor.authorAmat Santos, Ignacio J.
dc.contributor.authorNombela Franco, Luis
dc.contributor.authorSalinas, Pablo
dc.contributor.authorTeruel, Luis
dc.contributor.authorGómez Hospital, Joan Antoni
dc.contributor.authorArzamendi, Dabit
dc.contributor.authorTorres Sanabria, Mario
dc.contributor.authorCalle Pérez, Germán
dc.contributor.authorCañadas Pruaño, Dolores
dc.contributor.authorPérez de Prado, Armando
dc.contributor.authorBenito González, Tomás
dc.contributor.authorArroyo Úcar, Eduardo
dc.contributor.authorEstévez Loureiro, Rodrigo
dc.contributor.authorCaneiro Queija, Berenice
dc.contributor.authorIbañez Criado, José L.
dc.contributor.authorRuiz Nodar, Juan M.
dc.date.accessioned2022-02-07T17:24:01Z
dc.date.available2022-02-07T17:24:01Z
dc.date.issued2021-12-29
dc.date.updated2022-02-07T17:24:01Z
dc.description.abstractBackground: The Watchman FLX is a device upgrade of the Watchman 2.5 that incorporates several design enhancements intended to simplify left atrial appendage occlusion (LAAO) and improve procedural outcomes. This study compares peri-procedural results of LAAO with Watchman FLX (Boston Scientific, Marlborough, Massachusetts) in centers with varying degrees of experience with the Watchman 2.5 and Watchman FLX. Methods: Prospective, multicenter, 'real-world' registry including consecutive patients undergoing LAAO with the Watchman FLX at 26 Spanish sites (FLX-SPA registry). Implanting centers were classified according to the center's prior experience with the Watchman 2.5. A further division of centers according to whether or not they had performed ≤ 10 or > 10Watchman FLX implants was prespecified at the beginning of the study. Procedural outcomes of institutions stratified according to their experience with the Watchman 2.5 and FLX devices were compared. Results: 359 patients [mean age 75.5 (SD8.1), CHA2DS2-VASc 4.4 (SD1.4), HAS-BLED 3.8(SD0.9)] were included. Global success rate was 98.6%, successful LAAO with the first selected device size was achieved in 95.5% patients and the device was implanted at first attempt in 78.6% cases. There were only 9(2.5%) major peri-procedural complications. No differences in efficacy or safety results according to the centeŕs previous experience with Watchman 2.5 and procedural volume with Watchman FLX existed. Conclusions: The Watchman FLX attains high procedural success rates with complete LAA sealing in unselected, real-world patients, along with a low incidence of peri-procedural complications, regardless of operatoŕs experience with its previous device iteration or the number of Watchman FLX devices implanted.
dc.format.extent8 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec717891
dc.identifier.issn2352-9067
dc.identifier.urihttps://hdl.handle.net/2445/182998
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1016/j.ijcha.2021.100941
dc.relation.ispartofIJC Heart & Vasculature, 2021, vol. 38
dc.relation.urihttps://doi.org/10.1016/j.ijcha.2021.100941
dc.rightscc-by-nc-nd (c) Cruz González, Ignacio et al., 2021
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.sourceArticles publicats en revistes (Ciències Clíniques)
dc.subject.classificationFibril·lació auricular
dc.subject.classificationImplants artificials
dc.subject.otherAtrial fibrillation
dc.subject.otherArtificial implants
dc.titleImpact of operatoŕs experience on peri-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
717891.pdf
Mida:
973.34 KB
Format:
Adobe Portable Document Format