El CRAI romandrà tancat del 24 de desembre de 2025 al 6 de gener de 2026. La validació de documents es reprendrà a partir del 7 de gener de 2026.
El CRAI permanecerá cerrado del 24 de diciembre de 2025 al 6 de enero de 2026. La validación de documentos se reanudará a partir del 7 de enero de 2026.
From 2025-12-24 to 2026-01-06, the CRAI remain closed and the documents will be validated from 2026-01-07.
 
Carregant...
Miniatura

Tipus de document

Article

Data de publicació

Tots els drets reservats

Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/223351

Lung diffusing capacity after different modalities of exercise at sea level and hypobaric simulated altitude of 4000 m

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

Introduction: Lung diffusion capacity of carbon monoxide (DLCO) provides a measure of gas transfer in the lungs, which increase in relation to exercise and decrease in the presence of lung interstitial disease. The aim of this study is to evaluate the changes in lung diffusion after anaerobic and aerobic exercise in a cycle ergometer. Material and method: The participants were 11 healthy active subjects, including 8 females and 3 males (age: 24.3 ± 3.1 years). Lung diffusion capacity for carbon monoxide (DLCO) was studied under two different protocols: In the first day, DLCO was measured at SL at rest (SL-R), after 30-s maximal exercise (SL-ANA), and after 15-min moderate continuous exercise (SL-AER). In the second day, DLCO was evaluated at rest at SL, and then at HA (4,000 m) at rest (HA-R) and after 30-min of moderate interval exercise (HA-AER). Results: There was an increase in DLCO from rest to after SL-ANA (32.5 ± 6.4 to 40.3 ± 11.6 mL·min-1·mmHg-1, P = 0.027). In the second day, DLCO was evaluated at rest at SL, and then at HA (4,000 m) at rest (HA-R) and after 30-min of moderate interval exercise (HA-AER). During HA exposure, there was no changes in DLCO, either at HA-R, or after HA-AER. Conclusions: Lung diffusion capacity largely increased after 30-s maximal exercise in a cycle ergometer, although the O2 -dependence is small during this type of anaerobic exercise. Thus, exercise intensity may be a key modulator of the changes in lung diffusing capacity in relation to exercise.

Citació

Citació

GARCÍA ALDAY, Iker, DROBNIC, Franchek, ARRILLAGA, Beatriz, CHENG, Yinkiria, JAVIERRE GARCÉS, Casimiro f., PONS, Vicente, VISCOR CARRASCO, Ginés. Lung diffusing capacity after different modalities of exercise at sea level and hypobaric simulated altitude of 4000 m. _2023_. vol. 40. Vol. 5, núm. 286-292. [consulta: 7 de gener de 2026]. ISSN: 0212-8799. [Disponible a: https://hdl.handle.net/2445/223351]

Exportar metadades

JSON - METS

Compartir registre