Method for reducing specular reflections in Mueller matrix imaging

dc.contributor.authorPardo, Iago
dc.contributor.authorBian, Subiao
dc.contributor.authorPascual Miralles, Esther
dc.contributor.authorArteaga Barriel, Oriol
dc.date.accessioned2025-12-18T07:24:21Z
dc.date.available2025-12-18T07:24:21Z
dc.date.issued2025-05-12
dc.date.updated2025-12-18T07:24:22Z
dc.description.abstractMueller matrix polarimetry has emerged as a powerful tool for non-destructiveoptical analysis of biological tissues and bioorganic materials, offering detailed insights intopolarization-specific properties such as diattenuation, retardance, and depolarization. However,the accurate application of Mueller matrix polarimetry in biological media is often hindered byspecular reflections, which obscure signals from deeper tissue layers and degrade the samplevisualization and the polarimetric data quality. Existing methods to minimize specular reflectionhave limitations, especially in clinical or in vivo settings where sample positioning is constrained.Here, we introduce a new approach for avoiding or reducing specular highlights without havingto reduce light intensity. By using near-cross-polarization states between the polarization stategenerator and analyzer, we demonstrate that one can obtain an enhanced visualization of tissuestructures, reduce the appearance of specular reflections, and maintain a good polarimetriccontrast.
dc.format.extent11 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec759378
dc.identifier.issn1094-4087
dc.identifier.urihttps://hdl.handle.net/2445/225043
dc.language.isoeng
dc.publisherOptical Society of America
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1364/OE.557210
dc.relation.ispartofOptics Express, 2025, vol. 33, num.10, p. 21183-21193
dc.relation.urihttps://doi.org/10.1364/OE.557210
dc.rights(c) Optical Society of America, 2025
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.subject.classificationEl·lipsometria
dc.subject.classificationReflexió (Òptica)
dc.subject.classificationTeixits (Histologia)
dc.subject.classificationImatges mèdiques
dc.subject.otherEllipsometry
dc.subject.otherReflection (Optics)
dc.subject.otherTissues
dc.subject.otherImaging systems in medicine
dc.titleMethod for reducing specular reflections in Mueller matrix imaging
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
896972.pdf
Mida:
11.07 MB
Format:
Adobe Portable Document Format