Rapid biolayer interferometry measurements of urinary CXCL9 to detect cellular infiltrates noninvasively after kidney transplantation

dc.contributor.authorGandolfini, Ilaria
dc.contributor.authorHarris, Cynthia
dc.contributor.authorAbecassis, Michael
dc.contributor.authorAnderson, Lisa
dc.contributor.authorBestard Matamoros, Oriol
dc.contributor.authorComai, Giorgia
dc.contributor.authorCravedi, Paolo
dc.contributor.authorCremaschi, Elena
dc.contributor.authorDuty, J. Andrew
dc.contributor.authorFlorman, Sander
dc.contributor.authorFriedewald, John
dc.contributor.authorLa Manna, Gaetano
dc.contributor.authorMaggiore, Umberto
dc.contributor.authorMoran, Thomas
dc.contributor.authorPiotti, Giovanni
dc.contributor.authorPurroy, Carolina
dc.contributor.authorJarque, Marta
dc.contributor.authorNair, Vinay
dc.contributor.authorShapiro, Ron
dc.contributor.authorReid-Adam, Jessica
dc.contributor.authorHeeger, Peter S.
dc.date.accessioned2019-05-13T14:35:26Z
dc.date.available2019-05-13T14:35:26Z
dc.date.issued2017-11
dc.date.updated2019-05-13T14:35:27Z
dc.description.abstractIntroduction: measuring the chemokine CXCL9 in urine by enzyme-linked immunosorbent assay (ELISA) can diagnose acute cellular rejection (ACR) noninvasively after kidney transplantation, but the required 12- to 24-hour turnaround time is not ideal for rapid, clinical decision-making. Methods: we developed a biolayer interferometry (BLI)−based assay to rapidly measure urinary CXCL9 in <1 hour. We validated this new assay versus standard ELISA in 86 urine samples from kidney transplantation recipients with various diagnoses. We then used BLI to analyze samples from 56 kidney transplantation recipients, including 46 subjects who experienced an acute rise in serum creatinine associated with biopsy-proven ACR (n = 22), subclinical rejection (n = 15), or no infiltrates (n = 9), and 10 stable kidney transplantation recipients with surveillance biopsies. To assess its usefulness in detecting adequacy of therapy we serially measured serum creatinine and urinary CXCL9 in 6 subjects after treatment for ACR, and correlated the results with histological diagnoses on follow-up biopsies. Results: BLI accurately and reproducibly detected urinary CXCL9 in <1 hour. BLI-based results showed that urinary CXCL9 was >200 pg/ml in subjects with ACR and ≤100 pg/ml in subjects with stable kidney function without cellular infiltrates. In samples obtained after treatment for ACR, BLI CXCL9 measurements detected biopsy-proven intragraft infiltrates despite treatment-induced reduction in serum creatinine. Discussion: together, our proof-of-principle results demonstrate that BLI-based urinary CXCL9 detection has potential as a point-of-care noninvasive biomarker to diagnose and guide therapy for ACR in kidney transplantation recipients.
dc.format.extent8 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec676736
dc.identifier.issn2468-0249
dc.identifier.pmid29270527
dc.identifier.urihttps://hdl.handle.net/2445/133090
dc.language.isoeng
dc.publisherElsevier
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1016/j.ekir.2017.06.010
dc.relation.ispartofKidney International Reports, 2017, vol. 2, num. 6, p. 1186-1193
dc.relation.urihttps://doi.org/10.1016/j.ekir.2017.06.010
dc.rightscc-by-nc-nd (c) International Society of Nephrology, 2017
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.sourceArticles publicats en revistes (Ciències Clíniques)
dc.subject.classificationRebuig (Biologia)
dc.subject.classificationQuimiocines
dc.subject.classificationTrasplantament renal
dc.subject.classificationInterferometria
dc.subject.otherGraft rejection
dc.subject.otherChemokines
dc.subject.otherKidney transplantation
dc.subject.otherInterferometry
dc.titleRapid biolayer interferometry measurements of urinary CXCL9 to detect cellular infiltrates noninvasively after kidney transplantation
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
676736.pdf
Mida:
1.93 MB
Format:
Adobe Portable Document Format