dc.description.abstractThe present work investigates the influence of different biological and physical parameters on image quality (IQ) perception of the abdominal area in a modern PET scanner, using new reconstruction algorithms and testing the utility of a radiomics approach. Scans of 112 patients were retrospectively included. Images were reconstructed using both OSEM + PSF and BSRM methods, and IQ of the abdominal region was subjectively evaluated. First, 22 IQ related parameters were obtained (including count rate and biological or mixed parameters) and compared to the subjective IQ scores by means of correlations and logistic regression. Second, an additional set of radiomics features was extracted, and a model was constructed by means of an elastic-net regression. For the OSEM + PSF and especially for the BSRM reconstructions, IQ parameters presented only at best moderated correlations with the subjective IQ. None of the studied parameters presented a good predictive power for IQ, while a simple radiomics model increased the performance of the IQ prediction. These results suggest the necessity of changing the standard parameters to evaluate IQ, particularly when a BSRM algorithm is involved. Furthermore, it seems that a simple radiomics model can outperform the use of any single parameter to assess IQ.
dc.format.extent9 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec691043
dc.identifier.issn2045-2322
dc.identifier.pmid31337779
dc.identifier.urihttps://hdl.handle.net/2445/140920
dc.language.isoeng
dc.publisherNature Publishing Group
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1038/s41598-019-46937-8
dc.relation.ispartofScientific Reports, 2019, vol. 9, p. 10640
dc.relation.urihttps://doi.org/10.1038/s41598-019-46937-8
dc.rightscc-by (c) Reynes-Llompart, Gabriel et al., 2019
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es
dc.sourceArticles publicats en revistes (Ciències Clíniques)
dc.subject.classificationAvaluació
dc.subject.classificationDiagnòstic per la imatge
dc.subject.classificationCàncer
dc.subject.otherEvaluation
dc.subject.otherDiagnostic imaging
dc.subject.otherCancer
dc.titleImage quality evaluation in a modern PET system: impact of new reconstructions methods and a radiomics approach
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
691043.pdf
Mida:
1.39 MB
Format:
Adobe Portable Document Format