3D T1 turbo spin echo improves detection of gadolinium-enhancing multiple-sclerosis lesions

dc.contributor.authorNaval Baudin, Pablo
dc.contributor.authorBermúdez Bravo, William F.
dc.contributor.authorPineda-Borja, Vanessa I.
dc.contributor.authorArroyo Pereiro, Pablo
dc.contributor.authorMartínez Zalacaín, Ignacio
dc.contributor.authorRomero Pinel, Lucía María
dc.contributor.authorMora, Paloma
dc.contributor.authorCalvo Piñero, Natàlia
dc.contributor.authorMartínez Yélamos, Antonio
dc.contributor.authorMartínez Yélamos, Sergio
dc.contributor.authorCos Domingo, Mònica
dc.contributor.authorPons Escoda, Albert
dc.contributor.authorMajós Torró, Carlos
dc.date.accessioned2025-11-06T16:33:33Z
dc.date.available2025-11-06T16:33:33Z
dc.date.issued2025-10-03
dc.date.updated2025-11-06T16:33:33Z
dc.description.abstractObjectives: To compare the performance of 3D T1 turbo spin echo (3DT1TSE) and 3D T1 turbo field echo (3DT1TFE) MRI in detecting gadolinium-enhancing lesions in multiple sclerosis (MS). Materials and methods: We retrospectively analyzed 255 3-T MRIs from MS patients, each including post-contrast 3DT1TSE and 3DT1TFE sequences. Two blinded readers independently assessed enhancing lesions per sequence. A consensus review, incorporating longitudinal imaging and additional sequences, served as the reference standard. Results: The consensus identified 70 enhancing lesions in 31 patients. All 70 were visible on 3DT1TSE, while 64 (91%) were detectable on 3DT1TFE. Reader sensitivity was higher for 3DT1TSE (84% and 90%) than 3DT1TFE (45% and 40%) (p < 0.01). Inter-reader agreement was excellent for 3DT1TSE (ICC = 0.90) and moderate for 3DT1TFE (intraclass correlation coefficient = 0.69). Although false positives were more common with 3DT1TSE, they were readily excluded during consensus reading. In six patients, enhancing lesions were detected only on 3DT1TSE, with treatment escalation in two. Conclusion: 3DT1TSE outperformed 3DT1TFE in sensitivity and reader agreement for enhancing lesion detection in MS. Incorporating 3DT1TSE into standard MRI protocols may improve disease activity assessment and clinical decision-making. Critical relevance statement: Replacing 3D gradient-echo with post-contrast 3D T1 turbo spin-echo brain MRI greatly improves the detection of gadolinium-enhancing multiple-sclerosis lesions, boosting diagnostic sensitivity and reader agreement and directly influencing treatment-escalation decisions in routine practice. Key points: Detecting and enhancing MS lesions is limited by standard 3D T1 turbo field echo (3DT1TFE) MRI. 3D T1 turbo spin echo detects significantly more gadolinium-enhancing MS lesions than conventional 3DT1TFE. Greater lesion detection allows more precise activity assessment and optimal treatment management.
dc.format.extent11 p.
dc.format.mimetypeapplication/pdf
dc.identifier.issn1869-4101
dc.identifier.pmid41044229
dc.identifier.urihttps://hdl.handle.net/2445/224166
dc.language.isoeng
dc.publisherSpringer Open
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1186/s13244-025-02093-4
dc.relation.ispartofInsights into Imaging, 2025, vol. 16, num.1
dc.relation.urihttps://doi.org/10.1186/s13244-025-02093-4
dc.rightscc-by (c) Naval-Baudin, P. et al., 2025
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceArticles publicats en revistes (Ciències Clíniques)
dc.subject.classificationEsclerosi múltiple
dc.subject.classificationImatges per ressonància magnètica
dc.subject.classificationSubstàncies de contrast
dc.subject.otherMultiple sclerosis
dc.subject.otherMagnetic resonance imaging
dc.subject.otherContrast media (Diagnostic imaging)
dc.title3D T1 turbo spin echo improves detection of gadolinium-enhancing multiple-sclerosis lesions
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
904019.pdf
Mida:
2.94 MB
Format:
Adobe Portable Document Format