Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Document type

Article

Version

Published version

Publication date

Publication license

cc-by-nc-nd (c) Baz Alonso et al., 2024
Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/221686

First-In-Human Experience of the New Fully Repositionable IMPERIA Delivery System to Implant the ALLEGRA Transcatheter Heart Valve in Patients With Severe Calcific Aortic Stenosis or Degenerated Surgical Bioprosthesis: Thirty-Day Results of the EMPIRE I Study

Journal Title

Director/Tutor

Journal ISSN

Volume Title

Abstract

Background: The ALLEGRA (Biosensors International) transcatheter heart valve is a self-expanding supra-annular bovine pericardial aortic valve. A new delivery system (IMPERIATM, Biosensors International) has been designed which allows the valve to be fully resheathed and repositioned in situ. The aim of this premarket study was to assess the safety and efficacy of transcatheter aortic valve implantation using the combination of the CE (Conformite Europeenne) marked ALLEGRA valve and the new IMPERIA delivery system. Methods: One hundred thirty-seven patients were enrolled in 11 centers from January to November 2023. There were 30 roll-in patients, 91 in the intention-to-treat (ITT) population and 16 with degenerated surgical aortic bioprostheses. The primary outcome was device success according to the Valve Academic Research Consortium-2 from discharge up to 7 days in the ITT cohort. Results: Implantation of the ALLEGRA valve was successful in 136 patients (99.3%). There were no device embolizations and no patient required a second valve. Device success was achieved in 91.9% of the ITT cohort. At 30 days, all-cause mortality was 2.2% in the native aortic stenosis (AS) cohort and 0% in the valve-in-valve cohort. New pacemaker implantation was required in 12.4% (17/137). There was no patient prosthesis mismatch (PPM) in the 121 patients with native AS and moderate PPM in 2/16 valve-in-valve patients. Conclusions: This study confirms the safety and efficacy of transcatheter aortic valve implantation using the IMPERIA delivery system to implant the CE marked ALLEGRA transcatheter heart valve in patients with severe calcific native AS or a degenerated surgical aortic bioprostheses.

Citation

Citation

BAZ ALONSO, José Antonio, et al. First-In-Human Experience of the New Fully Repositionable IMPERIA Delivery System to Implant the ALLEGRA Transcatheter Heart Valve in Patients With Severe Calcific Aortic Stenosis or Degenerated Surgical Bioprosthesis: Thirty-Day Results of the EMPIRE I Study. Structural Heart. 2025. Vol. 9, num. 4. ISSN 2474-8714. [consulted: 13 of August of 2026]. Available at: https://hdl.handle.net/2445/221686

Export metadata

JSON - METS

Share record