Nondetection of SARS-CoV-2 on high-touch surfaces of public areas next to COVID-19 hospitalization units
| dc.contributor.author | Gavaldà Mestre, Laura | |
| dc.contributor.author | Ramírez Tarruella, Dolors | |
| dc.contributor.author | Gutiérrez Milla, Carme | |
| dc.contributor.author | Guillamet Roig, Ferran | |
| dc.contributor.author | Orriols Ramos, Rosa | |
| dc.contributor.author | Ragull Tisner, Sònia | |
| dc.contributor.author | Párraga Niño, Noemi | |
| dc.date.accessioned | 2021-06-17T12:56:41Z | |
| dc.date.available | 2021-06-17T12:56:41Z | |
| dc.date.issued | 2021-06-01 | |
| dc.date.updated | 2021-06-17T11:51:17Z | |
| dc.description.abstract | We studied the contamination with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and the bacterial load of high-touch surfaces located in public areas next to coronavirus disease (COVID-19) hospitalization units. Ninety-two samples were obtained from 46 different high-touch surfaces: 36 sites next to COVID-19 hospitalization units and 10 sites in the cabins of the public elevators. SARS-CoV-2 was not detected at any site, despite high bacterial loads suggested that the studied sites had been frequently touched prior to the sampling. | |
| dc.format.extent | 3 p. | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.pmid | 33450309 | |
| dc.identifier.uri | https://hdl.handle.net/2445/178513 | |
| dc.language.iso | eng | |
| dc.publisher | Elsevier B. V. | |
| dc.relation.isformatof | Reproducció del document publicat a: https://doi.org/10.1016/j.ajic.2021.01.007 | |
| dc.relation.ispartof | American Journal of Infection Control, 2021, vol. 49, num. 6, p. 840-842 | |
| dc.relation.uri | https://doi.org/10.1016/j.ajic.2021.01.007 | |
| dc.rights | (c) Association for Professionals in Infection Control and Epidemiology, 2021 | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | |
| dc.source | Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL)) | |
| dc.subject.classification | COVID-19 | |
| dc.subject.classification | SARS-CoV-2 | |
| dc.subject.other | COVID-19 | |
| dc.subject.other | SARS-CoV-2 | |
| dc.title | Nondetection of SARS-CoV-2 on high-touch surfaces of public areas next to COVID-19 hospitalization units | |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:eu-repo/semantics/publishedVersion |
Fitxers
Paquet original
1 - 1 de 1
Carregant...
- Nom:
- PIIS0196655321000079.pdf
- Mida:
- 267.56 KB
- Format:
- Adobe Portable Document Format