Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Document type

Article

Version

Published version

Publication date

Publication license

cc-by (c) Leitão Almeida, Bruno et al., 2020
Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/177141

Effect of crown to implant ratio and implantoplasty on the fracture resistance of narrow dental implants with marginal bone loss: an in vitro study

Journal Title

Director/Tutor

Journal ISSN

Volume Title

Abstract

Background: Peri-implantitis is a biological complication that affects soft and hard tissues around dental implants. Implantoplasty (IP) polishes the exposed implant surface, to decontaminate it and make it less prone to bacterial colonization. This study investigates whether a higher clinical crown-to-implant-ratio (CIR) reduces implant fracture resistance and whether implants are more fracture-prone after IP in the presence of 50% of bone loss. Methods: Forty-eight narrow platform (3.5 mm) 15 mm long titanium dental implants with a rough surface and hexagonal external connection were placed in standardized bone-like resin casts leaving 7.5 mm exposed. Half were selected for IP. The IP and control groups were each divided into 3 subgroups with different clinical CIRs (2:1, 2.5:1 and 3:1). The implant wall width measurements were calculated using the software ImageJ v.1.51 through the analysis of plain x-ray examination of all the samples using standardized mounts. A fracture test was performed and scanning electron microscopy was used to evaluate maximum compression force (Fmax) and implant fractures. Results: IP significantly reduced the implant wall width (P < 0.001) in all reference points of each subgroup. Fmax was significantly higher in the 2:1 subgroup (control = 1276.16 N ± 169.75; IP = 1211.70 N ± 281.64) compared with the 2.5:1 (control = 815.22 N ± 185.58, P < 0.001; IP = 621.68 N ± 186.28, P < 0.001) and the 3:1 subgroup (control = 606.55 N ± 111.48, P < 0.001; IP = 465.95 N ± 68.57, P < 0.001). Only the 2.5:1 subgroup showed a significant reduction (P = 0.037) of the Fmax between the controls and the IP implants. Most fractures were located in the platform area. Only 5 implants with IP of the 2:1 CIR subgroup had a different fracture location (4 fractures in the implant body and 1 in the prosthetic screw). Conclusions: IP significantly reduces the fracture resistance of implants with a 2.5:1 CIR. The results also suggest that the CIR seems to be a more relevant variable when considering the resistance to fracture of implants, since significant reductions were observed when unfavorable CIR subgroups (2.5:1 and 3:1 CIR) were compared with the 2:1 CIR samples.

Subject (English)

Citation

Citation

LEITÃO ALMEIDA, Bruno, et al. Effect of crown to implant ratio and implantoplasty on the fracture resistance of narrow dental implants with marginal bone loss: an in vitro study. BMC Oral Health. 2020. Vol. 20, num. 1, pags. 329. ISSN 1472-6831. [consulted: 16 of August of 2026]. Available at: https://hdl.handle.net/2445/177141

Export metadata

JSON - METS

Share record