Multicenter study of lumen-apposing metal stents with or without pigtail in endoscopic ultrasound-guided biliary drainage for malignant obstruction - BAMPI TRIAL: an open-label, randomized controlled trial protocol

dc.contributor.authorGarcia Sumalla, Albert
dc.contributor.authorLoras, Carme
dc.contributor.authorSanchiz, Vicente
dc.contributor.authorPedraza Sanz, Rafael
dc.contributor.authorVazquez Sequeiros, Enrique
dc.contributor.authorAparicio, Jose Ramon
dc.contributor.authorSerna Higuera, Carlos de la
dc.contributor.authorLuna Rodriguez, Daniel
dc.contributor.authorAndujar, Xavier
dc.contributor.authorCapilla, María
dc.contributor.authorBarberá, Tatiana
dc.contributor.authorForuny Olcina, José Ramón
dc.contributor.authorMartínez, Belen
dc.contributor.authorDura, Miguel
dc.contributor.authorSalord, Silvia
dc.contributor.authorLaquente, Berta
dc.contributor.authorTebe, Cristian
dc.contributor.authorVidela, Sebastià
dc.contributor.authorPerez Miranda, Manuel
dc.contributor.authorGornals Soler, Joan B.
dc.contributor.authorSpanish Working Group on Endoscopic Ultrasound Guided Biliary Drainage
dc.date.accessioned2022-03-25T08:35:02Z
dc.date.available2022-03-25T08:35:02Z
dc.date.issued2022-02-25
dc.date.updated2022-03-25T08:35:02Z
dc.description.abstractBackground It is unclear whether the insertion of an axis-orienting double-pigtail plastic stent (DPS) through biliary lumen-apposing meal stent (LAMS) in EUS-guided choledochoduodenostomy (CDS) improves the stent patency. The aim of this study is to determine whether this technical variant offers a clinical benefit in EUS-guided biliary drainage (BD) for the management of distal malignant biliary obstruction. Methods/design This is a multicenter open-label, randomized controlled trial with two parallel groups. Eighty-four patients with malignant biliary obstruction will undergo EUS-BD (CDS type) using LAMS in 7 tertiary hospitals in Spain and will be randomized to the LAMS and LAMS plus DPS groups. The primary endpoint is the rate of recurrent biliary obstruction, as a stent dysfunction parameter, detected during follow-up. Secondary endpoints: technical and clinical success (reduction in bilirubin > 50% within 14 days of stent placement), safety, and others (number of reinterventions, time to biliary obstruction, prognostic factors, survival rate). Discussion The BAMPI trial has been designed to determine whether the addition of a coaxial axis-orienting DPS through LAMS is superior to LAMS alone to prevent stent dysfunction.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec721967
dc.identifier.issn1745-6215
dc.identifier.pmid35216619
dc.identifier.urihttps://hdl.handle.net/2445/184396
dc.language.isoeng
dc.publisherBioMed Central
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1186/s13063-022-06106-1
dc.relation.ispartofTrials, 2022, vol. 23, num. 181
dc.relation.urihttps://doi.org/10.1186/s13063-022-06106-1
dc.rightscc-by (c) Garcia Sumalla, Albert et al., 2022
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceArticles publicats en revistes (Patologia i Terapèutica Experimental)
dc.subject.classificationAssaigs clínics
dc.subject.classificationMalalties del tracte biliar
dc.subject.classificationEndoscòpia
dc.subject.classificationColèstasi
dc.subject.otherClinical trials
dc.subject.otherBilious diseases and biliousness
dc.subject.otherEndoscopy
dc.subject.otherCholestasis
dc.titleMulticenter study of lumen-apposing metal stents with or without pigtail in endoscopic ultrasound-guided biliary drainage for malignant obstruction - BAMPI TRIAL: an open-label, randomized controlled trial protocol
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
721967.pdf
Mida:
1.36 MB
Format:
Adobe Portable Document Format